Plumbing Guideline Chart
The water feed line from the pump should use a minimum of 1½” PVC pipe. The feed line should terminate
near the center of the waterfall at the back of the bond beam. The Plumbing Guideline Chart in Table 2 will
aid in the design of the waterfall plumbing. In addition, Figure 9 shows the recommended optimum flow
pattern for a 24” waterfall.
Plumbing Guideline Chart
Use a minimum of 1-1/2” pipe
Use a minimum of 2” pipe for runs over 60’
Maximum Recommended Flow
1-1/2” Pipe
for 60 GPM
2” Pipe
for 100 GPM
2-1/2” Pipe
for 140 GPM
3” Pipe
for 225 GPM
Typical Performance at 50’ of Head
1/2 HP
26 GPM
3/4 HP
58 GPM
1 HP
68 GPM
1-1/2 HP
93 GPM
2 HP
106 GPM
3 HP
140 GPM
Table 2: Plumbing guideline charts for proper water flow.
Figure 9: 24” Waterfall Performance at 3 Foot elevation