All content © 2018, cmotion GmbH. All specifications are subject to change without further notice.
http://www.cmotion.eu
page 64 of 80
6.2.3.7.2.
LBUS devices
1
Device ID
2
Serial number
3
Software version
4
Bootloader version
5
Radio module ID / firmware version
6
Revision number
7
Built date
The LBUS device ABOUT menu shows you all relevant data about the connected LBUS
devices. Please select the LBUS device form the dynamic list of devices you want more
information on.
Note: Please have this data available, if contacting the cmotion support team with any
technical enquiries.
6.2.3.7.3.
Firmware update
The firmware update menu allows you to update your cPRO hand unit as well as other
connected LBUS devices.
Note: In order to perform an update, a USB stick formated in ExFAT or FAT32 loaded with
the appropriate update file for the cPRO hand unit or an other LBUS device needs to be
inserted in the USB slot on the back side of the cPRO hand unit. The USB drive will be
recognized and mounted automatically.
Please select cPRO hand unit if you want to update your hand unit or LBUS devices and
the corresponding LBUS device form the dynamic list if you want to update another LBUS
product. The update procedure is the same for any device as follows.
NOTICE
In order to update LBUS devices, the cPRO hand unit needs to be hard-wired to the
corresponding LBUS device using any LCB cable. The cPRO motor and cPRO camin can
also be updated through their CAM interface using the cable CAM (7p) - LBUS [K2.0015760].
Please select the update file form the USB drive which you want to up- or down-grade to.
1
2
3
4
6
5
7