background image

22 |

  FR

 

 

  FR

  | 23

CONSIGNES DE SÉCURITÉ

 

Avertissements  

23

Autocollant de sécurité  

24

Équipement de protection personnelle 

25

IMPORTANTES MESURES DE SÉCURITÉ

 

Branchement de l’appareil 

25

Mise à la terre 

25

Emploi d’une rallonge électrique 

25

Prévention des chocs électriques 

26

Consignes générales 

26

Emploi de produits chimiques 

26

COMPOSANTES DU SYSTÈME 

Unité de base Clorox® Total 360®

 

 27

Pistolet Clorox® Total 360® 

27

Buse du pistolet 

27

MODE D’EMPLOI 

Préparation des surfaces à traiter  

28

Démarrage et utilisation de l’unité 

28

Nettoyage par pulvérisation 

28

Changement de produit approuvé par Clorox  

28

Entretien et rangement après l’utilisation  

28

ENTRETIEN 

Chariot et compresseur 

29

Pompe péristaltique  

29

Buse du pistolet  

29

CARACTÉRISTIQUES 

30

DÉPANNAGE 

30

GARANTIE SUR L’ÉQUIPEMENT 

31

Table des matières

CONSIGNES DE SÉCURITÉ

Ce manuel contient des renseignements importants que vous 
devez lire et comprendre avant d’utiliser le pulvérisateur 
électrostatique Clorox® Total 360®. Ces renseignements portent 
sur la façon de vous protéger contre tout risque lié à l’emploi de 
l’appareil et d’en tirer le meilleur rendement possible. Il incombe 
au propriétaire de s’assurer que toutes les personnes appelées à 
utiliser le pulvérisateur lisent ce manuel.

Avertissements

Pour vous aider à repérer ce type de renseignements, nous utilisons  
les symboles ci-dessous pour vous alerter contre les dangers 
potentiels. Veuillez lire ce manuel attentivement et accorder une 
attention particulière aux symboles et aux avertissements fournis  
dans les encadrés. Ceux-ci servent à signaler et à prévenir toute 
situation potentiellement dangereuse pouvant causer la mort ou des 
blessures graves.

AVERTISSEMENTS

•  Bien lire et comprendre le manuel de l’utilisateur du 

pulvérisateur électrostatique Clorox® Total 360® avant d’utiliser 

l’appareil.

•  Bien lire et comprendre l’étiquette des produits liquides 

approuvés par Clorox avant de les utiliser avec le pulvérisateur 

électrostatique Clorox® Total 360®.

•  Le pulvérisateur électrostatique Clorox® Total 360® est conçu 

pour un usage commercial à l’intérieur comme à l’extérieur.

•  Le pulvérisateur électrostatique Clorox® Total 360® ne doit 

jamais être utilisé dans un environnement dangereux.

•  Le pulvérisateur électrostatique Clorox® Total 360® ne doit 

jamais être utilisé dans un milieu où des produits chimiques 

volatils sont présents, ni dans un endroit où des gaz, des 

vapeurs ou des particules sont présents à l’état volatil ou à des 

niveaux qui présentent un risque d’explosion.

•  Le pulvérisateur électrostatique Clorox® Total 360® ne doit 

jamais être utilisé par du personnel non formé.

AVERTISSEMENTS

DANGER : ÉQUIPEMENT PRESSURISÉ
Des fuites de liquide causées par un bris ou une rupture d’une 

composante du système peuvent éclabousser les yeux ou la peau 

de l’utilisateur et causer des blessures graves. Les précautions 

suivantes peuvent aider à prévenir les fuites ou la rupture d’une 

composante du système :

•  Vérifier chaque jour les tuyaux, les 

tubes et les raccordements. Remplacer 

immédiatement toute pièce usée ou 

endommagée.

AVERTISSEMENTS

DANGER POUR LES PIÈCES EN PLASTIQUE À L’EMPLOI  

DE SOLVANTS DE NETTOYAGE
De nombreux solvants peuvent dégrader les pièces en plastique  

et entraîner leur défaillance, ce qui peut causer des blessures 

graves ou endommager le système. Les précautions suivantes 

peuvent aider à prévenir ce type de dégradation chimique :

•  Utiliser uniquement des solvants compatibles 

à base d’eau pour nettoyer les pièces de 

plastique pressurisées.

•  Avant d’utiliser l’appareil, consulter 

les données techniques contenues 

dans ce manuel ou dans celui de tout 

autre équipement connexe. Prendre 

connaissance des fiches signalétiques et des 

recommandations propres aux liquides et 

aux solvants utilisés.

AVERTISSEMENTS

RISQUES D’INCENDIE, D’EXPLOSION ET DE CHOC ÉLECTRIQUE
Les émanations inflammables provenant des solvants ou de la 

peinture en milieu de travail peuvent prendre feu ou exploser. 

Les précautions suivantes peuvent aider à prévenir les risques 

d’incendie, d’explosion et de choc électrique :

•  L’équipement électrostatique doit être utilisé 

uniquement par des personnes formées et 

qualifiées, qui comprennent les instructions 

fournies dans ce manuel.

•  Cesser immédiatement d’utiliser l’appareil en 

présence d’étincelles statiques ou en cas de 

choc électrique. Ne pas utiliser le système 

tant que le problème n’a pas été identifié et 

corrigé.

•  Utiliser et nettoyer l’équipement uniquement 

dans un endroit bien aéré.

•  Ne jamais pulvériser de produit chimique 

inflammable (dont le point d’éclair est 

inférieur à 60 

°

C / 140 

°

F).

•  En présence d’émanations inflammables, 

ne pas brancher ni débrancher le cordon 

d’alimentation, et ne pas allumer ni éteindre  

de lumières.

•  S’il y a lieu, débarrasser la zone à traiter  

des déchets, solvants, guenilles, contenants 

d’essence et produits chimiques inflammables.

•  Garder en tout temps un extincteur 

d’incendie sur les lieux de travail.

Содержание Total 360 CLX1100

Страница 1: ... 31 For service and support contact Service Tech Team www servicetechteam com Para obtener servicio y apoyo comuníquese con el Equipo de Servicio Técnico en www servicetechteam com Pour communiquer avec notre équipe de services et de soutien techniques consultez son site Web à www servicetechteam com TM Clorox Total 360 Electrostatic Sprayer CLX1100 Atomizador Electrostático CLX1100 Pulvérisateur ...

Страница 2: ... environment Clorox Total 360 Electrostatic Sprayers should never be used in an area containing volatile chemicals Nor should they be used in any area containing volatile or explosive levels of gas vapor or particulates Clorox Total 360 Electrostatic Sprayers should never be used by untrained personnel WARNINGS PRESSURIZED EQUIPMENT HAZARD Fluid from equipment that leaks or ruptures from a compone...

Страница 3: ... plug Check with a qualified electrician to ensure you have the correct electrical service and grounding Grounding Instructions This appliance must be grounded In the event of malfunction or breakdown grounding provides a path of least resistance for an electric current to reduce the risk of electric shock This appliance is equipped with a cord having an equipment grounding conductor and a groundi...

Страница 4: ...quid products used in the Clorox Total 360 Electrostatic Sprayer 3 Know the length of time required by each liquid product application before allowing people and pets to return to the sprayed area 4 Tampering with Clorox approved products product containers and the Clorox Total 360 Electrostatic Sprayer in any form will void the customer warranty 5 To dispose of Clorox approved products refer to p...

Страница 5: ...ion 10 When spraying a second blue indicator light will illuminate on the sprayer instrument panel when the trigger is depressed NOTE Sprayer will automatically stay on until trigger is depressed an additional time NOTE Unit will not operate properly at 40 F 4 5 C or less Sprayer Operation During Cleaning 1 Position Clorox Total 360 Electrostatic Sprayer in a rear corner of the area 2 Direct the n...

Страница 6: ...able they should look to see if other devices are running on the same electrical circuit Power those off if necessary This could be a result of an underrated extension cord If an extension cord is being used remove and test the unit while using only the connected power cord See the extension cord section for more information Damage to liquid hose or peristaltic pump tubing Inspect the liquid line ...

Страница 7: ...se en un entorno peligroso Los Atomizadores Electrostáticos Clorox Total 360 nunca deben usarse en un área que contenga productos químicos volátiles Tampoco deben utilizarse en ningún lugar donde existen niveles de gases vapores o partículas volátiles o explosivas Los Atomizadores Electrostáticos Clorox Total 360 nunca deben ser utilizados por personal no entrenado ADVERTENCIAS PELIGRO DE EQUIPO P...

Страница 8: ...lizarse con un tomacorriente de 3 terminales con conexión a tierra clasificado para un servicio no inferior a 15A Siempre verifique esto antes de usar el producto Este aparato se utiliza en un circuito nominal de 120V 60Hz con un enchufe a tierra verificado Consulte con un electricista calificado para asegurarse de que tiene el servicio eléctrico y la conexión a tierra correctos TAPA DE LA CAJA DE...

Страница 9: ...ido utilizado en el Atomizador Electrostático Clorox Total 360 3 Conozca el tiempo requerido para cada aplicación de producto líquido antes de permitir que las personas y las mascotas vuelvan al área rociada 4 Cualquier alteración que se haga a los productos aprobados por Clorox contenedores de productos y el Atomizador Electrostático Clorox Total 360 anulará la garantía al cliente 5 Para desechar...

Страница 10: ...jo constante de la solución 10 Cuando esté rociando al presionar el gatillo se iluminará una segunda luz azul en el panel de instrumentos del atomizador NOTA El rociador permanecerá automáticamente encendido hasta que se vuelva a presionar el gatillo una vez más NOTA La unidad no funcionará correctamente a 40 F 4 5 C o menos Funcionamiento del Atomizador Durante la Limpieza 1 Coloque el Atomizador...

Страница 11: ...po de Servicio Técnico www servicetechteam com No rocía el rocío es irregular o débil Posible Problema Acción Correctiva No tiene la solución líquida Revise el recipiente del producto para ver el nivel de la solución y reemplácelo si está vacío Bloqueo en la boquilla o punta líquida Retire la cubierta de la boquilla y o la punta líquida para ver si hay obstrucciones El rocío parece débil El usuari...

Страница 12: ...présents ni dans un endroit où des gaz des vapeurs ou des particules sont présents à l état volatil ou à des niveaux qui présentent un risque d explosion Le pulvérisateur électrostatique Clorox Total 360 ne doit jamais être utilisé par du personnel non formé AVERTISSEMENTS DANGER ÉQUIPEMENT PRESSURISÉ Des fuites de liquide causées par un bris ou une rupture d une composante du système peuvent écla...

Страница 13: ...élémentaires pour réduire tout risque de brûlures d incendie de choc électrique de blessures et ou de mort Branchement de l appareil Le cordon d alimentation doit être branché dans une prise avec mise à la terre compatible avec les fiches à trois broches et homologuée pour 15 A minimum Toujours vérifier cette exigence au préalable Cet appareil est conçu pour un circuit nominal de 120 V 60 Hz avec ...

Страница 14: ... un grand nombre de produits chimiques liquides peuvent être dangereux s ils ne sont pas utilisés tel qu indiqué 1 Toujours porter un équipement de protection personnelle ÉPP à l emploi du pulvérisateur électrostatique Clorox Total 360 Consulter la fiche signalétique du produit utilisé pour connaître les besoins précis en ÉPP 2 Suivre les instructions de rangement de manipulation et de mise au reb...

Страница 15: ... pendant 20 secondes environ jusqu à ce que le débit soit constant 10 Lorsque l utilisateur appuie sur la gâchette un deuxième voyant bleu s allume sur le tableau de commande du pistolet REMARQUE Le pistolet restera automatiquement sous tension jusqu à ce que l utilisateur appuie sur la gâchette une fois de plus REMARQUE L unité ne donne pas son plein rendement à une température de 4 5 C 40 F ou m...

Страница 16: ... liquide est épuisée Vérifier le niveau de liquide dans le contenant et si celui ci est vide le remplacer Quelque chose obstrue la buse ou l embout Retirer le couvre buse et ou l embout de la buse pour vérifier si quelque chose y est resté logé ou coincé Le jet manque de puissance L utilisateur doit éteindre l appareil le débrancher et le brancher de nouveau dans une autre prise de courant Si aucu...

Страница 17: ...W9 1SE United Kingdom Tel 44 0 208 614 7120 Fax 44 0 208 940 2040 consumerservices clorox co uk Clorox Australia Pty Ltd Level 3 10 Herb Elliott Avenue Sydney Olympic Park NSW 2127 Phone 1300 731 030 Clorox New Zealand Ltd Level 8 Building 5 Central Park 660 670 Great South Road Penrose Auckland 1061 Phone 0800 108 858 NI 45092 TM Electrostatic Sprayer CLX1100 Atomizador Electrostático CLX1100 Pul...

Отзывы: