4.8
JOBS MANAGEMENT
Personalised welding settings, or JOBs, can be saved in memory locations and subsequently uploaded. Up to 50 JOBS can be saved (j01-j50).
JOBs can be managed only when the unit is not in welding mode.
The SETUP menu settings cannot be saved by means of the JOBs.
When a JOB is loaded and an UP/DOWN torch is installed, press the torch triggers to select the saved JOBS.
If there are no JOBS loaded, the UP/DOWN buttons on the torch serve to adjust the welding current.
4.8.1
SAVING A JOB
S5
Hold down the button for 3 seconds.
SA. Job
The message appears on the following displays: D1-D2
S5
Press the button to confirm.
SA. J.xx
The message appears on the following displays: D1-D2
xx= number of the first free job.
E1
Use the encoder to select the required job number.
On selecting a currently occupied memory location, the job number flashes.
If you confirm at this point, the new job will overwrite the previously saved settings.
Exit without confirmation
Press any button (except S5).
This action will automatically close the menu.
Exit with confirmation
S5
Press the button.
This action will automatically close the menu.
4.8.2
LOADING A USER JOB OF FACTORY SET JOB
S5
Press and release the button.
Lo. J.xx
Only when the jobs have been uploaded, the message is shown on the following displays: D1-D2
xx= number of the latest job used.
no Job
If there are no jobs in the memory the message is shown on the following displays: D1-D2
E1
Use the encoder to select the number of the job to be uploaded.
Exit without confirmation
Press any button (except S5).
This action will automatically close the menu.
Exit with confirmation
S5
Press the button.
J.xx
The message appears on the following displays: D2
xx= number of loaded job.
The LED illuminates.
This action will automatically close the menu.
4.8.3
DELETING A JOB
S5
Hold down the button for 3 seconds.
SA. Job
The message appears on the following displays: D1-D2
E1
Select the following setting with the encoder:
Er. Job
The message appears only if there are saved JOBS, on the following displays: D1-D2
S5
Press the button to confirm.
Er. J.xx
The message appears on the following displays: D1-D2
xx= number of the latest job used.
E1
Use the encoder to select the number of the job to be deleted.
Exit without confirmation
Press any button (except S5).
This action will automatically close the menu.
Exit with confirmation
S5
Press the button.
This action will automatically close the menu.
Содержание GLW 322
Страница 1: ...operating instructions and spare parts GLW 322 Rev 0 EN...
Страница 8: ...GLW 322 Cod 006 0001 1861 01 09 2014 v2 0 ENGLISH 7 38 polarity to basic electrode...
Страница 10: ...GLW 322 Cod 006 0001 1861 01 09 2014 v2 0 ENGLISH 9 38 polarity for tungsten electrode...
Страница 38: ...Remote Controller Potentiometer 2k 10k Foot pedal controller Potentiometer 2k 10k...
Страница 39: ...www qineo de...