Cod.006.0001.1861
01/09/2014 v2.0
ENGLISH
GLW 322
28/38
4.6
PARAMETERS SETTING: (2ND LEVEL)
S2
Press this button to scroll the list of settings to edit.
The acronym relative to the setting to be edited appears on the following displays: D1
The value relative to the selected setting appears on the following displays: D2
E1
Using the encoder, edit the value of the selected setting.
The value is saved automatically.
Press any key (except S2) to save the setting and quit the menu.
Tab. 9 - Parameters of the 2nd level menu: MMA mode
ACRONYM
PARAMETER
MIN DEFAULT MAX
Urd
OUTPUT VOLTAGE REDUCTION oFF
oFF
on
U.EL.
LONG ARC VOLTAGE
37
47
65
rC
REMOTE CONTROLLER ACTIVATION oFF
oFF
on *1
S2
Hold down the button for 3 seconds to gain access to the 2nd level menu.
The acronym relative to the setting to be edited appears on the following displays: D1
The value relative to the selected setting appears on the following displays: D2
S2
Press this button to scroll the list of settings to edit.
E1
Using the encoder, edit the value of the selected setting.
The value is saved automatically.
Press any key (except S2) to save the setting and quit the menu.
Tab. 10 - Parameters of the 2nd level menu: CONTINUOUS DC TIG mode, PULSED DC TIG mode, SYNERGIC DC TIG mode
ACRONYM
PARAMETER
MIN DEFAULT MAX
SP.t.
SPOT TIG TIME
0.01 s 0.01 s 10.0 s
HF
HF ARC STRIKE ENABLE
on
on
oFF
rC
REMOTE CONTROL ACTIVATION on
oFF
on *2
r.P.C.
MINIMUM PEDAL CURRENT
1 %
5 %
90 %
Tab. 11 - 2nd level menu parameters in AC TIG mode
ACRONYM
PARAMETER
MIN
DEFAULT
MAX
AC
AC WAVEFORM
1
1
9
VALUE
DC+
WAVEFORM
DC-
1
sine
sine
2
rectangular
rectangular
3
triangular
triangular
4
sine
rectangular
5
rectangular
sine
6
sine
triangular
7
triangular
sine
8
rectangular
triangular
9
triangular
rectangular
SP.t.
SPOT TIG TIME
0.01 s
0.1 s
10.0 s
HF
HF ARC STRIKE ENABLE
on
on
oFF
rC
REMOTE CONTROL ACTIVATION
on
oFF
on
*2
r.P.C.
MINIMUM PEDAL CURRENT
1 %
5 %
90 %
*1: Remote control types:
-
manual remote controller.
*2: Remote control types:
-
UP/DOWN or potentiometer TIG torch.
-
foot pedal controller.
The maximum and minimum TIG welding current values can be set with the foot pedal controller.
The up slope and down slope cannot be controlled via the foot pedal.
The following welding procedures can be selected with the foot pedal:
2T LIFT ARC - 2T HF - 2T SPOT - 2T SPOT HF
Содержание GLW 322
Страница 1: ...operating instructions and spare parts GLW 322 Rev 0 EN...
Страница 8: ...GLW 322 Cod 006 0001 1861 01 09 2014 v2 0 ENGLISH 7 38 polarity to basic electrode...
Страница 10: ...GLW 322 Cod 006 0001 1861 01 09 2014 v2 0 ENGLISH 9 38 polarity for tungsten electrode...
Страница 38: ...Remote Controller Potentiometer 2k 10k Foot pedal controller Potentiometer 2k 10k...
Страница 39: ...www qineo de...