![Cloos GLW 322 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/cloos/glw-322/glw-322_operating-instructions-and-spare-parts_2625801011.webp)
Cod.006.0001.1861
01/09/2014 v2.0
ENGLISH
GLW 322
10/38
3
COMMISSIONING
3.1
USER INTERFACE
CODE
SYMBOL
DESCRIPTION
L1
Illuminates to show a value in the following unit of measurement:
AMPERES
L2
Illuminates to show the last voltage and current values measured during welding.
The value appears on the following displays: D1-D2
The LED switches off when a new welding procedure is started, or when any of the welding settings is modified.
L3
Illuminates to show a value in the following unit of measurement:
VOLTS
L4
This LED illuminates to confirm the presence of power on the output sockets.
L5
This LED illuminates to show an anomaly in the operating conditions.
See § 3.6 ALARMS MANAGEMENT page 16.
L6
Illuminates to show a value in the following unit of measurement:
MILLISECONDS/SECONDS
L7
Illuminates to show a value in the following unit of measurement:
HERTZ
L8
Illuminates to show a value in the following unit of measurement:
AMPERES
L9
Illuminates to show a value in the following unit of measurement:
PERCENTAGE
L10
Illuminates to show a value in the following unit of measurement:
MILLIMETRES
L11
This LED indicates that the current reference setting is imposed by the remote controller.
L12
DC TIG mode:
When this LED illuminates the following parameter can be set:
Q-START
AC TIG mode:
When this LED illuminates the following parameter can be set:
MIX AC
L13
DC TIG mode:
When this LED illuminates the following parameter can be set:
DYNAMIC ARC
AC TIG mode:
When this LED illuminates the following parameter can be set:
FUSIONE EXTRA
L14
DC TIG mode:
When this LED illuminates the following parameter can be set:
MULTI TACK
AC TIG mode:
When this LED illuminates the following parameter can be set:
AC FREQUENCY
L15
AC TIG mode:
When this LED illuminates the following parameter can be set:
AC TIG BALANCE
L16
AC TIG mode:
When this LED illuminates the following parameter can be set:
ELECTRODE DIAMETER
L17
When this LED illuminates the following parameter can be set:
STARTING CURRENT
L18
When this LED illuminates the following parameter can be set:
SLOPE UP
Содержание GLW 322
Страница 1: ...operating instructions and spare parts GLW 322 Rev 0 EN...
Страница 8: ...GLW 322 Cod 006 0001 1861 01 09 2014 v2 0 ENGLISH 7 38 polarity to basic electrode...
Страница 10: ...GLW 322 Cod 006 0001 1861 01 09 2014 v2 0 ENGLISH 9 38 polarity for tungsten electrode...
Страница 38: ...Remote Controller Potentiometer 2k 10k Foot pedal controller Potentiometer 2k 10k...
Страница 39: ...www qineo de...