![Cloos GLC 353 MC3 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/cloos/glc-353-mc3/glc-353-mc3_operating-instructions-manual_2625799023.webp)
B-5
Operation
GLC 353/503 MC3
Signal lamps:
The operation panel has two signal lamps:
-
Start
-
Temp (overtemperature)
Signal lamp Start indicates that the Weld signal was given.
The signal can be given:
-
via torch trigger
-
externally
-
in the operating mode E(lectrode) manual
Caution !
Open circuit voltages exists on connection lugs P and N or on
the welding wire or electrode !
Signal lamp Temperature indicates that the operation temperature of
the following components has been exceeded:
-
Welding transformer
-
Welding rectifier
-
Transistor cascade
-
Cooling water pump
-
Fan
The welding process cannot be continued if the operating temperature of a component has
been exceeded. Restart is only possible when the overloaded component has cooled
down.
Display 1
The following values are indicated
on the display:
-
Welding voltage
-
Wire feed speed
-
Plate thickness
The value can be selected with the selector key. LED's show the values selected.
LEDs
Selector key
B1.1 Operating and display elements Power source
Содержание GLC 353 MC3
Страница 2: ......
Страница 6: ...4 GLC 353 503 553 MC3 Operating instructions...
Страница 8: ...6 GLC 353 503 553 MC3 Operating instructions...
Страница 18: ......
Страница 28: ...B 10 Operation GLC 353 503 MC3...
Страница 40: ...B 22 Welding GLC 353 503 553 MC3...