ZEFNET Pro User Manual
24
ZEFNET PRO FEATURES
Breaker Balancing
Breaker Balancing allows a ZEFNET Pro to share power on a single
set of conductors supplied by one circuit breaker.
When only one plug
is charging a vehicle, the full charging capacity is available to that vehicle.
When both plugs are charging vehicles, each plug will offer 50% of the
circuit capacity to each vehi
cle (thus “sharing” the circuit breaker).
WARNING: BREAKER SETUP NEEDS TO BE COMPLETED IN THE
ZEFNET CLOUD SOFTWARE BEFORE BREAKER BALANCING WILL
BE ENABLED.
Breaker Balancing Operating Instructions
1. Connect Vehicle #1 to either plug #1 or plug #2 with the
corresponding SAE-J1772TM connector. Vehicle #1 will have access
to the full power available through that circuit.
2. Connect Vehicle #2 to the remaining plug with the SAE-J1772TM
connector. Each vehicle will now have access to half of the power
available through that circuit.
3. If one vehicle disconnects or completes charging, the other vehicle
will have access to the full circuit power after 15 seconds.