HCS Optional Features User Manual
30
Figure 14: COSMOS ChargeGuard EX Controls: 15 Wire
Table 9: COSMOS ChargeGuard EX Wiring: 15 Wire
ChargeGuard EX Wire
Color
Ungrounded
Grounded
ChargeGuard Enable
Blue/BK Standard operation
ChargeGuard EX mode
External Activate
Red/BK
Charge not allowed Allows charging session
To enable COSMOS
ChargeGuard EX, wire the Green ground wire
included in the 15-wire harness to the ChargeGuard EX Blue/BK
wire as indicated in
Table 9
and shown in the
Figure 15
.
Figure 15: Enable COSMOS ChargeGuard EX: 15 Wire
COSMOS ChargeGuard EX Activation Instructions: 15
Wire
1. Connect the charge cord to the vehicle
2. Momentarily (> 0.1 second) ground the External Activate
wire (Red/BK) to ground (Green and Blue/BK)
This COSMOS ChargeGuard EX activation will make the station
available for charging until it is disconnected from the vehicle.
This allows for higher vehicle functionality such as delayed
charging and cabin conditioning.
Leaving the COSMOS EX Activate line grounded allows for
continuous use the charging station regardless of how many times
it is connected or disconnected from various vehicles.