COSMOS ChargeGuard EX: 10 Wire Instructions
The COSMOS
ChargeGuard EX can be wired for either one time
access or for continuous access until disabled. Control wires for a
10 wire harness are Grey and Violet, as shown in
Figure 16
and
Table 10
.
NOTE:
If an electric vehicle is connected when a
COSMOS
ChargeGuard EX turns on after a power failure,
one charge session will be allowed to accommodate for
power outages.
Figure 16: COSMOS ChargeGuard EX Controls: 10 Wire
Figure 17: Enable COSMOS ChargeGuard EX: 10 Wire
Table 10: COSMOS ChargeGuard EX Wiring: 10 Wire
ChargeGuard EX Wire
Color Ungrounded
Grounded
ChargeGuard Enable
Grey
Standard operation
ChargeGuard EX mode
External Activate
Violet Charge not allowed
Allows charging session
To enable COSMOS
ChargeGuard EX, wire the Green ground wire
included in the 10-wire harness to the ChargeGuard EX Grey wire
as indicated
Table 10
and shown in the
Figure 17
.