HCS Optional Features User Manual
17
Figure 7: Share2 Connect Vehicle #1
HCS 1
HCS 2
Vehicle 1
Full Circuit Power Available (100%)
Vehicle 2
Not charging (0%)
Share2 Operating Instructions
1. Connect Vehicle #1 to either HCS #1 or HCS #2 with
the corresponding SAE J1772 connector. Vehicle #1
will have access to the full power available through that
circuit.
2. Connect Vehicle #2 to the remaining EVSE with the
SAE J1772 connector. Each vehicle will now have
access to half of the power available through that
circuit.
3. If one vehicle disconnects or completes charging, the
other vehicle will have access to the full circuit power
after 15 seconds.