www.directed.com
18
installer-programmable features (1 chirp=off, 2 chirps=on)
To access the installer-programmable features, follow the programming steps 1-4 on
the previous page and then continue to hold the
button for 10 seconds until you
hear three chirps.
system check/troubleshooting
1.
Start the car.
2.
Open and close the door.
3.
Press/release the brake.
z
Wait 25 seconds. You should hear 5 chirps. If not, go to step 1 below.
z
The brake lights will begin flashing. If not, go to step 2 below.
z
30 seconds later, the siren should sound and car’s engine should die if the
engine is at or below the programmed RPM or speed level. If not, go to step
3 below.
z
Once the car is disabled, enter the valet code to disarm. If the system does
not disarm, go to step 4 below.
SStteepp 1
1 - BlackJax not initializing
1.
Check the door trigger connection and polarity.
2.
Check the brake trigger.
SStteepp 2
2 - Brake lights not flashing
1.
Check brake light connection.
2.
Check to make sure that the 20 amp fuse on the RED/WHITE wire is OK.
Feature Select Description
*1
Not used
*2
Program Speed (see
Speed Programming
)
*3
Not used
*4
Door Trigger Polarity (N
Neeggaattiivvee/Positive) (1
1 cchhiirrpp/2 chirps)
*5
Program RPM (see
RPM Programming
)
*6
Auxiliary Siren Output (Constant/PPuullsseedd) (1 chirp/2
2 cchhiirrppss)
Содержание BlackJax 5
Страница 4: ...www directed com 4...