background image

User- Programmable Fea tures

User-Programmable Features (1 Chirp = OFF, 2 Chirps = ON)

Fea ture

Select

Unmarked 1 

Unmarked 2

Unmarked 3

Unmarked 4

✱ 

Add New Remote 

NOTE 1

Chirps

(Off/

On

/Quiet*)

(1 chirp/

2 chirps

/3

chirps)

AutoArming

(

On

/Off)

Arm/Disarm with

Secondary

Remote

NOTE 5

  2

Personalized Siren

Sounds*

NOTE 2

NOT USED

AutoArm & Lock

(On/

Off)

Trunk Release

with

Secondary

Remote

NOTE 6

 3 

P lay Si ren Sounds*

(

Always

/Trigger

Only)

(

1 chirp

/2 chirps)

Remote Valet Feature

(

On

/Off)

NOT USED

Silent

Arm/Disarm with

Secondary

Remote

NOTE 6

  4

Siren Duration

(

30/

60/90

seconds)

AutoStart

Neither/Battery/Tempe

rature/Both

)

(

1 chirp

/2 chirps

/

3

chirps/4 chirps)

 

(Requires IntelliStart 4)

FACT

(Off/

On)

NOT USED

  5

AutoLock

(Off/

On

/RPM)

(1 Chirp/

2

Chirps

/3 Chrrps)

(IntelliStart 4

required for RPM

dependent door

locking)

NOT USED

NOT USED

Remote Start with

Secondary

Remote

(Requires

IntelliStart 4)

NOTE 6

  6

AutoUnlock

(

On

/Off)

Clear All Remotes

 

NOTE 4

NOT USED

Window

Rolldown/Venting

 with Secondary

Remote

(Requires 

SmartWindows 4)

NOTE 6

  7

Re set All to Fac tory

Set tings (ex cept

re mote controls

and valet code)

NOTE 3

Valet Code

SHOULD ONLY BE

PROGRAMMED BY

THE VEHICLE OWNER

NOT USED

Remote Valet

Mode

 with Secondary

Remote

NOTE 6

                                                                  

*Requires Self-Powered SmartSiren 4

Con tin ued...

15

Содержание ACE 2000

Страница 1: ......

Страница 2: ...rmation and for wiring diagrams and servicing information on older Clifford products 24 hour AutoFax 1 800 444 4667 24 hour dealer website www clifforddealer com Clifford Electronics Inc n 20750 Lasse...

Страница 3: ...al Zone Piezo Sensor 8 Trunk Trigger 8 Parking Lights 8 Auxiliary A with Selectable Output Type and AutoActivation 10 Starter or Ignition Immobilization Circuit 10 High Output Siren 10 Hood Trigger 11...

Страница 4: ...WIRE 7 Discuss placement of the LED valet switch window decals etc with the vehicle owner prior to installation 8 DO NOT mount components nor route wires near hot or moving vehicle parts Clifford com...

Страница 5: ...d Pro oPoint and Click Feature Programming oComplete Online System Diagnostics At A Glance oHigh Output Siren oRemote Door Locking Unlocking oRemote Panic with Smart Locking Unlocking oBuilt In Dual P...

Страница 6: ...4...

Страница 7: ...unit be installed under the hood or other similarly hostile environment 1 Select an area behind the dash to mount the control unit using wire ties but do not permanently affix it until all wiring and...

Страница 8: ...or lock servos will result If you require assistance call the Clifford Technical Support Helpline PRIOR to wiring the door locks If the vehicle is not equipped with power door locks you may optionally...

Страница 9: ...Door Locks Continued 5 On a vacuum pump type Mercedes Benz or Audi make the connections shown in Door Lock Unlock Diagram 6 then if 1989 or older program the system for a 3 second lock pulse 7...

Страница 10: ...a rotating sleeve firmly screw the sensor to the interior firewall kick panel or trunk wall Make certain that the adjustment screw is accessible 2 Mate the sensor to the connector on the wireloom with...

Страница 11: ...one of the following locations nNear the headlight switch nIn the door sill harness going to the rear lights nAt any of the four Parking Light bulbs 2 If working underdash be sure to turn the dashligh...

Страница 12: ...close the power windows sunroof you can make them automatically close upon remote arming 1 Find the wire that shows either 12V or when the key is held to lock in the door cylinder 2 Tap a wire in to t...

Страница 13: ...ctor connect the wireloom s YELLOW wire to the BLACK siren wire 3 Connect the RED wire through the 5A fuse coming from the battery positive cable clamp as indicated in the diagram on page 4 Engine Bay...

Страница 14: ...t FACT simply 1 Arm the system with the remote control 2 Wait 10 seconds after the interior light turns off then trigger the trigger zone the Dual Zone Piezo Sensor to activate the siren 3 Do not disa...

Страница 15: ...osed to moisture and check the trigger wire for possible shorting Programmable Features ACE 2000 comes from the factory with its features preprogrammed as noted in bold text in the tables on pages 1 4...

Страница 16: ...the same number of chirps as the column number you have selected audibly confirming your selection 6 Within five seconds select the feature row Press and release the button the same number of times as...

Страница 17: ...Siren Duration 30 60 90 seconds AutoStart Neither Battery Tempe rature Both 1 chirp 2 chirps 3 chirps 4 chirps Requires IntelliStart 4 FACT Off On NOT USED 5 AutoLock Off On RPM 1 Chirp 2 Chirps 3 Ch...

Страница 18: ...lifford system that uses ACG 2 technology to arm or disarm the vehicle For instance to set the button combination of the other car s master remote control to arm disarm the system select column 4 row...

Страница 19: ...A On Off 5 Program RPM Requires Optional IntelliStart 4 Program Optional SmartWindows 4 Program Door Polarity Positive Negative 1 chirp 2 chirps NOTE 1 Once this feature is selected you will hear one...

Страница 20: ...d the Delayed Courtesy Lights feature has not been programmed on Disarm with the remote control enter the vehicle and turn on the ignition The LED will flash 1 10 times pause then repeat the same numb...

Страница 21: ...to step 6 nDoors do not lock You either selected the wrong door lock diagram connected the wires incorrectly or a servo may be required Reconnect the vehicle s power locking system to its original con...

Страница 22: ...hirps once If the siren does not chirp once refer to step 3 nParking lights flash once If the parking lights do not flash once refer to step 4 nLED stops flashing If not refer to step 6 nDoors unlock...

Страница 23: ...ay need to be inverted Step 12 Test the hood trigger circuit Arm the system then open the hood The following should occur nSiren sounds immediately parking lights flash repeatedly This is the correct...

Страница 24: ...ransmitting Make sure that the voltage at the control unit between the 5A fused power line and each of the two ground lines measures at least 12 0 volts if less make sure both grounds are solid if the...

Страница 25: ...23...

Отзывы: