Recycling and disposal

The WEEE symbol means that this product and batteries must be 

disposed separately from other household waste. When they 

reach their end of life, take them to a designated waste collection 

point in your area to guarantee a safe disposal or recycling. Protect 

the environment, human health and natural resources!

Alarm silence facility

When the smoke alarm has detected smoke and turns into the alarm 

mode, you can mute the alarm for a minimum of 5 minutes and a 

maximum 15 minutes by pressing the test panel. After that, the smoke 

alarm automatically resets and returns into the normal operation mode. 

If there are still particles of combustion in the air, the smoke alarm will 

turn into the alarm mode again. WARNING: Use this function only if you 

are absolutely sure that the alarm was triggered by a known problem, 

e.g. smoke development during cooking.

Low battery mode

When the battery is running low, the smoke alarm will indicate this with 

a repetitive beep and flash for approximately 30 days. WARNING: This 

smoke alarm is equipped with a non-replaceable battery. When this 

warning occurs, replace the device as soon as possible! The acoustic low 

battery warning signal can be muted for ten hours by pressing the test 

panel. The smoke alarm is still functioning and able to detect smoke 

when it's in this mode.

Fault warning mode

The smoke alarm runs through a periodical self-test. When the smoke 

sensor is not functioning properly, it will turn into the sensor fault 

warning mode. Try cleaning the smoke alarm (see paragraph 

“Maintenance”) or replace the smoke alarm!

If the buzzer is not working correctly, the device will turn into the buzzer 

fault warning mode. Please immediately contact the manufacturer or 

replace the smoke alarm when this occurs.

Night mode

This smoke alarm has an automatic night mode. In dark rooms, the led 

signal will be dimmed to prevent disturbance of the night's sleep.

USER MANUAL

Identification

ESSENTIAL CHARACTERISTICS: PASSED

Nominal activation conditions/ Sensitivity, Response delay (response time) and

Performance under fire condition - Operational reliability - Tolerance to supply voltage

- Durability of operational reliability and response delay, temperature resistance,

vibration resistance, humidity resistance, corrosion resistance, electrical stability

EN 14604:2005 + AC:2008

Product type 

: Slimline 10yr Smoke Alarm

Product code 

: OM546H-LS

Manufactured for  : Newfield Group Ltd

 

  491 Waterloo Road

 

  Islington, Christchurch 8042

 

  New Zealand

Website 

: www.orcasafety.co.nz

Operating mode 

Visual signal (flash) 

Acoustic signal (beep) 

Description mode

Normal 

1 x per 40 second 

None 

Device is func

ti

oning properly

Test 

1 x per second (3 x) / 

1 x per seconds (3 x) / 

Device is tested

 

pause of 1,5 seconds 

pause of 1,5 seconds

Alarm 

1 x per second (3 x) / 

1 x per seconds (3 x) / 

Device is detec

ti

ng smoke

 

pause of 1,5 seconds 

pause of 1,5 seconds

Alarm silence 

1 x per 8 seconds 

None 

Smoke alarm signal is muted

Low battery warning 

1 x per 40 seconds 

1 x per 40 seconds 

Battery is running low

Low battery warning silence 

None 

None 

Low battery warning is muted

Sensor fault warning 

1 x per 40 seconds 

1 x per 40 seconds 

Sensor is not func

ti

oning properly

Buzzer fault warning 

2 x per 40 seconds 

None 

Buzzer is not func

ti

oning properly

Overview visual & acoustic signals

Maintenance

•  This smoke alarm is equipped with a self-testing mechanism. We 

recommend to test the smoke detector manually at least once every 

three months by using the test facility. If the smoke alarm functions 

correctly, it will generate a loud beep. Due to the loudness of the 

alarm, make sure that you always stand at arm’s length distance from 

the unit when you are testing. If the smoke alarm does not generate 

an acoustic signal, the smoke alarm must be replaced immediately!

•  Clean the smoke alarm at least once per month to remove dirt, dust or 

debris. Use a vacuum cleaner with a soft brush and vacuum all sides 

and covers of the smoke alarm. Do not remove the top cover of the 

smoke alarm to clean it inside.

•  Do not attempt to repair this smoke alarm. If the smoke alarm shows a 

damage related to its functionality, it must be replaced!

•  Trouble shooting: False alarm is often caused by insect penetration, 

dust or steam.

Disassembling

To disassemble the smoke alarm, take a screw driver and push it into the 

mounting hole. Then, turn the smoke alarm counterclockwise to remove 

it from the mounting bracket.

Thank you for purchasing our smoke alarm!

Before using the device, please read these instructions carefully to 

ensure proper usage and store them in a safe place during the entire 

lifetime of the product.

Product description and intended use

This is a smoke alarm with a photoelectric sensor for installation in 

residential buildings, apartments and rooms with residential-like use. 

Smoke alarms are designed to provide an early warning of emergency 

fires to persons present, so that these persons can react appropriately to 

the hazardous event. Always consult local regulations for smoke alarms.

Product specifications

Detection method 

: Photoelectric sensor

Power supply 

: Sealed battery 3V DC (included)

Battery lifetime 

: 10 years

Alarm volume 

: ≥ 85 dB (A) at 3 meters

Alarm sensitivity 

: 0.11 - 0.16 dB/m

Monitored area 

: 40 m²

Operating temperature 

: 0°C - 40°C

Operating humidity 

: < 93 %

Date of replacement 

: See product label

Individual alarm indicator 

: Yes

Alarm silence facility 

: Yes | Hush time: 5-15 minutes

Low battery warning 

: Yes

Low battery silence facility 

: Yes | Hush time : 10 hours

Installation in leisure

   accommodation vehicles 

: Yes

Mounting location 

: Ceiling or wall

Interconnectable 

: No

Warnings

•  To prevent injury, this device must be securely attached to the 

ceiling/wall in accordance with the installation instructions.

•  Batteries should not be exposed to excessive heat such as sunshine, 

fire or the like.

•  Do not paint or cover the smoke alarm.

•  In rooms with simple sloped, peaked or gabled ceilings, install smoke 

alarms on the ceiling 900mm (3 feet) from the highest point of the 

ceiling. “Dead air” at the peak of a ceiling may prevent the smoke 

from reaching the alarm in time to provide an early warning.

Where not to install a smoke alarm

•  In an environment with a high risk of draught (e.g. close to air 

conditioning, fans and ventilation outlets). The movement of air can 

impair the penetration of fire smoke into the smoke alarm.

•  Areas where fumes or cooking smoke occur, such as kitchens.

•  Areas with high humidity such as bathrooms, or close to appliances 

such as dish washers or washing machines.

•  Areas where dust can accumulate such as the garage or attic.

Mounting

•  Place the mounting plate on the desired installation location and mark 

where the holes should be drilled.

•  Drill two holes with a diameter of 5 millimetres.

•  Push the plastic plugs into the holes.

•  Insert the screws into the mounting plate, and tighten them firmly into 

the plugs.

•  Place the smoke alarm on the mounting bracket and secure it by 

turning it clockwise.

Activation

Before commissioning the 

smoke alarm, it is 

important to activate it 

and test it for correct 

operation.

•  When fixing the alarm 

body to the bracket the 

alarm is automatically 

activated.

•  Press the full face test 

panel and hold it in for 

approximately 3 

seconds until the alarm 

siren sounds. Release 

the test panel 

immediately a

ft

er this. 

The smoke alarm will 

generate a beep to 

indicate that it's 

activated.

Where to install a smoke alarm

•  As a minimum, smoke alarms should be located between sleeping 

areas and potential sources of fire such as living rooms and kitchens. 

In single story homes with one sleeping area, a smoke alarm should be 

installed in the hallway, as close as possible to the living 

accommodation. To ensure audibility in bedrooms, no smoke alarm 

should be further away than 3m from any bedroom door. It may be 

necessary to install more than one smoke alarm, particularly if the 

hallway is more than 15m long. In single story homes with two 

separate sleeping areas, a minimum of two smoke alarms is required, 

one outside each sleeping area. In multilevel or split level homes, as a 

minimum a smoke alarm should be installed on the ground floor 

between the staircase and any rooms in which a fire might start and 

on each story in circulation areas which form part of escape route 

(normally hallways and landings).

•  Additional alarms should be installed in bedrooms in anticipation of 

fires originating there, caused by faulty wiring, lights, appliances, 

smokers or other hazards.

•  For best protection, smoke alarms should be installed in every room in 

your home, apart from those listed in the next section. Heat alarms 

should be used in kitchens, boiler rooms, laundry rooms, garages and 

such like, where smoke alarms would be unsuitable.

•  Install smoke alarms in circulation areas at a distance no greater than 

7.5m from the farthest wall, no greater than 7.5m from a door to any 

room in which a fire might start and no greater than 7.5m from the 

next smoke alarm.

•  As it is impossible to predict the source of a fire, the best location for 

an alarm is usually the center of a room or hallway. If it is necessary to 

place a smoke alarm on a wall, always locate the detection element of 

the alarm 150mm to 300mm (6 to 12 inches) below the ceiling and the 

bottom of the alarm above the level of doors and other openings.

PHOTOELECTRIC SMOKE ALARM

LONG-LIFE SEALED BATTERY

OM546H-LS