De layed Cour tesy Lights
Some vehicles have a courtesy light delay or dimming circuit, which interferes with an alarm being
able to detect the door trigger upon remote arming. If the delay or dimming lasts more than 5
seconds, no special connections or testing are needed, simply turn on the
Delayed Courtesy Lights
feature as noted in the
Installer-Programmable Features
section on page 16. Please note that
the Door Ajar Warning feature will not be available.
Re mote Con trol Op era tion
The ACE 2000 comes with two ergonomically designed remote controls. Up to a total of four
Clifford ACG 2 remote controls can be programmed into the ACE 2000 (older Clifford ACG
and non-ACG remotes are not compatible with the ACE 2000). For information on how to
use the remote controls, see the
ACE 2000 User’s Manual.
FACT—False Alarm Con trol and Test
The system microprocessor automatically checks for another activated sensor or trigger before
sounding the siren a second time, thus preventing any further false alarms. If you wish to test
FACT, simply:
1. Arm the sys tem with the re mote con trol.
2. Wait 10 seconds after the interior light turns off, then trigger the trigger zone the
Dual-Zone Piezo Sensor to activate the siren.
3. Do not disarm the system, let the siren complete its cycle.
4. Trigger the sensor again. The alarm should be silent.
5. Unlock and open a door. The alarm should sound immediately. You may now disarm.
Eight- Event To tal Re call
The system’s nonvolatile memory records the identity of the last eight activated or
malfunctioning triggers and sensors.
NOTE: The CliffNet Wizard Pro Installation software dis plays the Eight- Event
To tal Re call data in a graphi cal for mat.
1. With the ignition OFF, press and hold the unmarked side of the PlainView 2 Switch.
2. Transmit channel 1 to “arm,” and then again to “disarm,” and then release the button.
3. The LED will flash 1–10 times, pause, then flash 1–10 times, etc. Write down the number
of flashes in each cycle.
12
Func tion
Press But ton(s)
Arm/Disarm
Activate Auxilliary A*
(usually remote trunk release)
Silent Arm/Disarm
+
✱
Optional IntelliStart 4 Accessory*
✱
Enable/Disable Remote Valet Mode*
+
✱
Optional SmartWindows 4 Accessory*
+
*These channels can be assigned to control
another Clifford ACG 2 system on another vehicle.