115 VAC is sent to the condensate solenoid and cold water is sent to the condensate
spray nozzle pulling the steam down the drain.
•
When the steam pressure drops below the operating set point the heat circuit is energized
and the heat process begins again.
11.
The unit is turned off by depressing the red rocker switch.
•
115 VAC is removed from the timing and heat circuits.
•
115 VAC is removed from the normally open blowdown valve allowing the unit to
drain.
•
115 VAC is sent to the 3-minute timer.
•
The three-minute timer will energize the fill and rinse solenoids for 3 minutes while
the steamer drains assisting and cooling the blowdown. .