PROBLEM:
24CGP10
Timer displays "PAUS" ("Sure Cook" light is on) and won't count down
START
Is steam heating
the cooking
cabinetabove 192
degrees (the set
temp of the
thermo-switch)?
Does the timer
count down when
the thermo-switch
is bypassed?
Yes
See
24CGP10 Stops
Producing
Steam
No
Replace the
timer
No
Replace the
thermo-switch
Yes
PROBLEM:
24CGP10
Steam leaks around the door.
Steam Leaks
Around Door
Is
COLD
water
supplied to the
steamer?
Supply
cold water (35-
60 PSI) to the
steamer.
No
Is the door gasket
physically
damaged?
Yes
Turn over the
gasket or
replace it.
Yes
Is the door out of
alignment?
No
Replace the
door bearings
and pins.
Yes
Is the drain
obstructed?
No
Remove the
obstruction
Yes
Is there 120 VAC
across the coil of
the condensate
solenoid?
No
Replace the
compartment
thermostat
No
Is the solenoid
opening?
Yes
Replace the
condensate
solenoid.
No
Replace the
condensate spray
nozzle
Yes