Cleveland SteamCraft Power 10 Скачать руководство пользователя страница 13

Replace the

 on/off rocker

switch

Yes

Connect 115

VAC to

steamer.

No

Is the red light on

in the on/off

switch?

Is there 115 VAC

to the steamer?

Is there water in

the sight glass?

Yes

See

Steamer won't

fill.

No

Yes

PROBLEM:

24CGP10 Boiler

won't build

pressure

No

Boiler won't build

pressure

Is the red "Low

Water"  light on?

Yes

Is the red "Low

Water"  light on

with a jumper from

terminals LOW

and C on the water

board?

Replace the

water board.

Is the Amber light

on in the reset

switch?

No

Is there 120 VAC

between

terminals L2 and

HTR on the water

board?

Yes

Repair

 or Replace the

probe circuit.

No

Is there 120 VAC

between terminals

L2 and HTR on the

water board with a

jumper between

LOW and C?

Is there 120 VAC

to the Reset

switch?

Repair

 or Replace the

probe circuit.

Replace the
water board

Replace the

Reset switch

Yes

After depressing
the reset switch,

does the Amber

light go off?

With the High

Limit pressure

switch

temporarily

bypassed, does

the Amber light go

off when the reset

switch is

depressed?

No

Yes

No

Replace

 the high limit

pressure

 switch

Replace the R1

relay.

Is there 120 VAC

to the primary of

the 24 VAC

ignition

transformer?

No

Yes

Replace the R1

relay

No

Yes

Is there 120 VAC

to the primary of

the ignition

transformer with

the operating

pressure switch

temporarily

bypassed?

No

Replace the R1

relay

Replace

 the operating

pressure

switch

Is there 24 VAC at

the secondary  of

the transformer?

Yes

Is there flame at

the burner?

With

flame and water the

Boiler is making

steam.  Check for

leaks.

Is there allot of

steam coming out

the drain?

Yes

Replace the

steam trap

Yes

No

See 

Boiler

won't ignite.

No

Replace the

ignition

transformer

No

No

Yes

No

Yes

No

Yes

Is there 24 VAC at

ignition module?

Yes

Is the blower

turning?

Replace the air

prover switch

No

Yes

Is there 120 VAC

to blower ?

No

Replace the

blower

Yes

Is there 24 VAC to

coil of R2?

No

Replace float

switch

Replace R2

relay

No

Yes

Yes

Содержание SteamCraft Power 10

Страница 1: ...technical and technological changes revisions or updates Cleveland Range LLC assumes no liability or responsibility regarding errata changes revisions or updates Qualified Cleveland Range LLC Authoriz...

Страница 2: ...Cleveland Range LLC 1333 East 179th St Cleveland Ohio U S A 44110 Ph 1 216 481 4900 Fx 1 216 481 3782 Visit our Web Site at www clevelandrange com...

Страница 3: ...ounded for 20 seconds 115 VAC is removed from HTR and sent back to IND energizing the low water light 3 When the momentary amber switch is depressed 115 VAC is sent to the R1 relay closing it The norm...

Страница 4: ...mer begins to count down 115 VAC is sent to the condensate solenoid and cold water is sent to the condensate spray nozzle pulling the steam down the drain When the steam pressure drops below the opera...

Страница 5: ...ized and the heat process begins again 11 The unit is turned off by depressing the red rocker switch 115 VAC is removed from the timing and heat circuits 115 VAC is removed from the normally open blow...

Страница 6: ......

Страница 7: ......

Страница 8: ...closed R1 contacts to energize the amber light If the low water cut off probe is not grounded for 20 seconds 115 VAC is removed from HTR and sent back to IND energizing the low water light 3 When the...

Страница 9: ...cted around the product and pulled down the drain by the condensate spray When the cooking compartment reaches 193 degrees internally the thermal switch closes and the timer begins to count down 115 V...

Страница 10: ...ing the steam down the drain 11 The unit is turned off by depressing the red rocker switch 115 VAC is removed from the timing and heat circuits 115 VAC is removed from the normally open blowdown valve...

Страница 11: ......

Страница 12: ......

Страница 13: ...es the Amber light go off With the High Limit pressure switch temporarily bypassed does the Amber light go off when the reset switch is depressed No Yes No Replace the high limit pressure switch Repla...

Страница 14: ...solenoid Replace the fill solenoid Yes Is water leaving the fill solenoid Replace wiring to drain solenoid Does the steamer have the optional intermittent blowdown timer Replace the wiring to the int...

Страница 15: ...terminal is there 1 0 micro amp DC to the ignition module No Is there flame at the pilot assy Yes Yes No Replace pilot assy and ignition wire Yes Yes Replace the pilot assy and ignition wire No Boile...

Страница 16: ...t See Boiler won t ignite Yes Is the low water indicator on 120 VAC bewtween the IND and L2 terminals on the waterboard Clean or replace the low water probe Is high pressure switch opening prematurely...

Страница 17: ...eam leaks around the door Steam Leaks Around Door Is COLD water supplied to the steamer Supply cold water 35 60 PSI to the steamer No Is the door gasket physically damaged Yes Turn over the gasket or...

Страница 18: ...1333 East 179th Street Cleveland Ohio 44110 Phone 216 481 4900 Fax 216 481 3782...

Страница 19: ......

Страница 20: ......

Страница 21: ......

Страница 22: ......

Страница 23: ......

Отзывы: