PROBLEM:

24CGP10

Gas Boiler Over

Pressurizes

(15# Safety

valve opens)

Boiler over

pressurizes

Does operating

pressure switch

open at proper

setting (check

service manual for

that steamer)?

Replace

operating

pressure

switch

No

Does the burner
continue to burn

with operating

pressure switch

open?

Yes

Replace gas

valve.

Yes

Does the pressure

in the gauge

continue to rise
with no burners

on?

No

Descale boiler

Yes

No

Replace the

safety valve.

PROBLEM:  24CGP10  Stops Producing Steam

Steamer stops

steaming

Does the amber
light in the reset

switch  come on?

Is the temperature

sensitive dot

(surrounded by a

yellow circle) on

the water board

white?

Replace

 the water board.  It has

reached a temperature of

over 180
degrees.

Yes

No

The

ignition module

has gone into

lockout. See

Boiler won't

 ignite

Yes

Is the low water

indicator on (120

VAC bewtween

the IND and L2

terminals on the

waterboard )?

Clean or

replace the low

water probe

Is high pressure

switch opening

prematurely?

Replace high

pressure switch

Delime the

boiler

No

Yes

No

Does the steamer start to

steam when the operating

pressure switch is

temporarily 

by-passed?

No

Replace the

operating pressure

switch

Yes

No

Does the low

water indicator

light go off  with  a

jumper btween the

LOW and C

terminals on the

waterboard?

Yes

Yes

Replace the

water board

No

Does the Boiler
build pressure?

No

With the cabinet in

the timed position and

time on the timer is
the 120 VAC to the

steam solenoid?

Yes

Replace Steam

Solenoid

Yes

With the cabinet in

the manual

postion is there
120 VAC to the

steam solenoid?

No

Replace the

timer

Yes

With the optional

door switch  by

passed, is there

120 VAC to the

steam solenoid?

No

Replace the

door switch

Yes

Replace the

timed/manual

switch

No

Содержание SteamCraft Power 10

Страница 1: ...technical and technological changes revisions or updates Cleveland Range LLC assumes no liability or responsibility regarding errata changes revisions or updates Qualified Cleveland Range LLC Authoriz...

Страница 2: ...Cleveland Range LLC 1333 East 179th St Cleveland Ohio U S A 44110 Ph 1 216 481 4900 Fx 1 216 481 3782 Visit our Web Site at www clevelandrange com...

Страница 3: ...ounded for 20 seconds 115 VAC is removed from HTR and sent back to IND energizing the low water light 3 When the momentary amber switch is depressed 115 VAC is sent to the R1 relay closing it The norm...

Страница 4: ...mer begins to count down 115 VAC is sent to the condensate solenoid and cold water is sent to the condensate spray nozzle pulling the steam down the drain When the steam pressure drops below the opera...

Страница 5: ...ized and the heat process begins again 11 The unit is turned off by depressing the red rocker switch 115 VAC is removed from the timing and heat circuits 115 VAC is removed from the normally open blow...

Страница 6: ......

Страница 7: ......

Страница 8: ...closed R1 contacts to energize the amber light If the low water cut off probe is not grounded for 20 seconds 115 VAC is removed from HTR and sent back to IND energizing the low water light 3 When the...

Страница 9: ...cted around the product and pulled down the drain by the condensate spray When the cooking compartment reaches 193 degrees internally the thermal switch closes and the timer begins to count down 115 V...

Страница 10: ...ing the steam down the drain 11 The unit is turned off by depressing the red rocker switch 115 VAC is removed from the timing and heat circuits 115 VAC is removed from the normally open blowdown valve...

Страница 11: ......

Страница 12: ......

Страница 13: ...es the Amber light go off With the High Limit pressure switch temporarily bypassed does the Amber light go off when the reset switch is depressed No Yes No Replace the high limit pressure switch Repla...

Страница 14: ...solenoid Replace the fill solenoid Yes Is water leaving the fill solenoid Replace wiring to drain solenoid Does the steamer have the optional intermittent blowdown timer Replace the wiring to the int...

Страница 15: ...terminal is there 1 0 micro amp DC to the ignition module No Is there flame at the pilot assy Yes Yes No Replace pilot assy and ignition wire Yes Yes Replace the pilot assy and ignition wire No Boile...

Страница 16: ...t See Boiler won t ignite Yes Is the low water indicator on 120 VAC bewtween the IND and L2 terminals on the waterboard Clean or replace the low water probe Is high pressure switch opening prematurely...

Страница 17: ...eam leaks around the door Steam Leaks Around Door Is COLD water supplied to the steamer Supply cold water 35 60 PSI to the steamer No Is the door gasket physically damaged Yes Turn over the gasket or...

Страница 18: ...1333 East 179th Street Cleveland Ohio 44110 Phone 216 481 4900 Fax 216 481 3782...

Страница 19: ......

Страница 20: ......

Страница 21: ......

Страница 22: ......

Страница 23: ......

Отзывы: