The Troubleshooting Guide is a list of symptoms of problems that may occur during routine operation.

“Problem” (left column) lists common operating problems.

“Possible Cause” (center column) lists causes of problems in the order they should be checked.

“Remedy / Reference” (right column) lists fixes for problems from easiest to hardest.

“Notes” in “Remedy / Reference” column are at end of the Troubleshooting Guide.

ATTEMPTING TO REPAIR OR CORRECT PROBLEMS REQUIRING A QUALIFIED CLEVELAND RANGE AUTHORIZED 

SERVICE REPRESENTATIVE VOIDS THE WARRANTY

Troubleshooting Guide

Problem

Possible Cause

Remedy/Reference

Switch light does not turn on when 
POWER switch is pressed.

Power turned off at main disconnects.

Turn on power at main disconnect switch. 

POWER switch light on and steam 
generator does not fill.

Water supply to steamer shut off. 

Open water supply valves. 

Water line strainer is clogged.

Clean water supply strainer.

Water sensors shorted by scale, deposits.

Descale steam generator with USDA approved 
descaler.

Inoperative controls or solenoid.

See note #1.

Steam generator does not make any 
steam.

No water in steam generator.   

See steam generator does not fill (above).

Gas models only

Gas supply valve closed.

Electric models only

Heating elements covered with scale.

Turn off steam generator and open gas supply 
valve. Refer to Service Manual. 
Descale steam generator with USDA approved 
descaler.

Electric models only

Heating elements damaged.

See note #1.

Water sensors covered by scale deposits.

Descale steam generator with USDA
approved descaler.

Inoperative controls.

See note #1.

Abnormal amount of steam coming 
from drain.

Hot water instead of cold water connected to 
condenser fitting.

Make proper connections. Refer to Installation 
Manual.

Water supply to condenser turned off.

Open water supply valve.

Condenser water line strainer is clogged.

Clean out condenser water supply line.
See note #1.

Water supply line to the condenser blocked, 
broken, or leaking.

Repair or replace solenoid. See note #1. 

Inoperative condenser solenoid.

Replace solenoid. See note #1.

Inoperative controls.

Turn off electricity at main disconnect switch.
See note #1.

Steam and/or water draining around 
compartment door

Drain clogged or covered.

Clean drain with USDA approved drain cleaner.

Door gasket or door parts worn.

See note #1.

Steamer not level.

See note #2.

Hot water to condenser.

See note #2.

Reduced steam flow into cooking 
compartment.

Steam generator scale buildup.

Descale steam generator with approved 
descaler.

Steam nozzle scale buildup.

See note #1.

Steam solenoids scale buildup

See note #1.

Electric models only

Voltage too low for unit.

See note #4.

Electric models only

Faulty heating element or controls.

See note #1.

Steam flow does not stop when timer 
stops.

Operating in manual mode.

Switch to timed mode for timer to be effective.

Stuck open steam valve.

See note #1.

Inoperative controls inside cabinet.

Turn off electricity at main disconnect switch. 
See note #1.

Troubleshooting

23

Содержание 36-CDM-16

Страница 1: ...new information and models are released Visit our website for the latest manual ConvectionPro Steamers Part KE004033 2 C MODEL 36CGM16 36CEM16 36CSM16 36CDM16 For your future reference Model ________...

Страница 2: ...nformer aux mesures de s curit normalis es de l industrie y compris mais sans s y limiter les r glementations de l OSHA les proc dures de d branchement verrouillage tiquetage relatives tous les servic...

Страница 3: ...juste modificaci n servicio o mantenimiento puede ocasionar da os a la propiedad lesiones o muerte Lea detenidamente las instrucciones de instalacion y de operaci n antes de instalar poner a funcionar...

Страница 4: ...de presi n Keep clear of pressure relief discharge Restez l cart de la soupape de suret Permanezca alejado de la descarga de presi n Do not lean on or place objects on the equipment Ne vous penchez p...

Страница 5: ...team Generators Direct Steam Connected Steamers Kettles Installation Check 8 Gauge Pressure Reading 9 OPERATION 9 Controls and Controls Panels 9 Start up and Preheat 12 Cooking Operations 13 The Key P...

Страница 6: ...call the gas supplier from a phone away from the building Follow the gas supplier s instructions If the gas supplier cannot be reached call the fire department C Operational Safety The Operational Saf...

Страница 7: ...a qualified Cleveland Range authorized service representative BURN and SCALD HAZARD Exposure to steam condensate and hot surfaces can cause death burns and scalds To avoid injury Do NOT breathe steam...

Страница 8: ...authorized service representative Model Number________________________________________________________ Serial Number____________________________________________________________ Write the Serial Number...

Страница 9: ...combustible areas that have provisions for adequate air supply The term boiler will be used synonymously with steam generator 2 Position For proper operation and drainage the equipment must be level...

Страница 10: ...on Toe data contained in step 5 for a ld water also applies to hot water 5 Connect COLD water supply plumbing to the line strainer Never Connect hot water to the boiler water fill line strainer Consta...

Страница 11: ...s than 14 Water column Installation must be in accordance with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 1984 Installation in Canada must be in accordanc...

Страница 12: ...roughly before connecting it to the boiler To ensure an adequate volume of steam the branch steam supply line must be 3 4 inch IPS minimum Connect the inverted bucket trap to the outlet end of the ste...

Страница 13: ...ts verify that there is a 115 Volt connection at the handi box located on the left side of the base at the bottom front 8 On steam coil units the incoming steam pressure must be 35 to 50 psi Less than...

Страница 14: ...wner s and operator s for future reference Controls and Control Panels There are two steam generator control arrangements and two steamer compartment control panels available for Cleveland Range Conve...

Страница 15: ...10...

Страница 16: ...11 Control Panels Key Pad Control Panel Dial Timer Control Panel...

Страница 17: ...n Pro XVI steamer cooking compartments For accurate efficient cooking times the cook ing compartments should be preheated during startup a Close the compartment door by gently swinging it shut b Refer...

Страница 18: ...y from the steamer when first opening the door Do not look into the cooking compartment until steam has cleared Keep hands out of the cooking compartment to prevent burns 13 Manual Cooking Operation K...

Страница 19: ...he timer for 1 hour and 15 minutes Change 1 hour 60 min and 15 minutes to 75 minutes Press the following number keys in sequence 7 5 0 0 The display will read 75 00 when properly set for 1 hour and 15...

Страница 20: ...using timed or manual cooking modes optimum steam heat transfer and therefore a higher quality food product is achieved when shallow per forated uncovered pans are used Manual Cooking Operation Dial...

Страница 21: ...artment steaming cycle Use automatic mode when an exact cooking time is required Stearn cooking begins when the timer is set and automatically stops when the timer counts down to zero 1 Check that the...

Страница 22: ...ter boils away as steam When allowed to accumulate the water becomes highly mineralized which results in erratic operation lime build up corrosion and premature electric heater failures In some cases...

Страница 23: ...freely through the compartment drain openings If it does not the drain must be cleaned before using the steamer 4 To prolong door gasket life always leave compartment door ajar when not in use 5 Exter...

Страница 24: ...ed serviceman Once every three months the cold water line strainer should be cleaned Cleveland Range supports a comprehensive network of Maintenance and Repair Centers regional parts and service distr...

Страница 25: ...d Timer Settings are followed Steaming fresh vegetables on perforated pans gives best results Two to three institutional packages of frozen vegetables will fit into one 12 x 20 x 2 Cafeteria Pan ADDIT...

Страница 26: ...5 lb block peeled In Minutes Fresh Frozen 4 12 4 6 Lobster whole 1 lb 7 9 Lobster tails 8 oz defrosted butterflied Mussels in shell 2 Oysters in shell 2 4 5 6 3 4 4 6 2 4 6 8 8 10 4 6 4 5 7 4 6 4 5 10...

Страница 27: ...er and juicy and when served is the same size as the rare steak Sirloin patties chopped 8 oz Aibeye 8 oz Top butt steak 6 oz 8 oz Fllet Mignon butterflied 4 oz 6 oz 8 oz 10 oz 16 oz whole Chateaubrian...

Страница 28: ...ved descaler Electric models only Heating elements damaged See note 1 Water sensors covered by scale deposits Descale steam generator with USDA approved descaler Inoperative controls See note 1 Abnorm...

Страница 29: ...h too much food Put less food in pan Use fewer pans Voltage too low for unit See note 4 Suggested cooking times are usually listed for cooking at sea level Extend cooking times for altitudes above 250...

Страница 30: ...itchencare com To learn how Welbilt Foodservice and its leading brands can equip you visit our global web site at www welbilt com then discover the regional or local resources available to you Every n...

Отзывы: