Cleveland 36-CDM-16 Скачать руководство пользователя страница 2

STATEMENT OF RESPONSIBILITIES /

DÉCLARATION DES RESPONSABILITÉS / 

DECLARACIÓN DE RESPONSABILIDADES

This document is for use by experienced
and trained Qualified Cleveland Range,
LLC Authorized Service Representatives
who are familiar with both the safety
procedures, and equipment they
service. Cleveland Range, LLC assumes
no liability for any death, injury,
equipment damage, or property damage
resulting from use of, improper use of,
or failure to use the information
contained in this document. Cleveland
Range, LLC has made every effort to
provide accurate information in this
document, but cannot guarantee that
this document does not contain
unintentional errors and omissions.

The information in this document may
be subject to technical and
technological changes, revisions, or
updates. Cleveland Range, LLC
assumes no liability or responsibility
regarding errata, changes, revisions, or
updates.

Qualified Cleveland Range, LLC
Authorized Service Representatives are
obligated to follow industry standard
safety procedures, including, but not
limited to, OSHA regulations, and
disconnect / lock out / tag out
procedures for all utilities including
steam, and disconnect / lock out / tag
out procedures for gas, electric, and
steam powered equipment and / or
appliances.

All utilities (gas, electric, water and
steam) should be turned OFF to the
equipment and locked out of operation
according to OSHA approved practices
during any servicing of Cleveland Range
equipment

Qualified Cleveland Range, LLC
Authorized Service Representatives are
obligated to maintain up-to-date
knowledge, skills, materials and
equipment. 

Ce document est destiné à l’usage des
Représentants de Service qualifiés et
autorisés de Cleveland Range, LLC qui
possèdent l’expérience et la formation ainsi
que la bonne connaissance des mesures
de sécurité et du matériel qu’ils
entretiennent.

Cleveland Range, LLC décline toute
responsabilité pour tout cas de décès,
blessure, dommage matériel ou dommage
aux biens résultant de l'utilisation, de la
mauvaise utilisation ou du manquement
d’utilisation des renseignements contenus
dans ce document.

Cleveland Range, LLC s’est efforcé à
fournir des renseignements précis dans ce
document mais ne peut garantir que ce
document soit exempt d’erreurs et
d’omissions non intentionnelles. 

Les renseignements contenus dans ce
document peuvent être assujettis à des
changements techniques et technologiques,
des révisions ou des mises à jour. 

Cleveland Range, LLC décline toute
obligation ou responsabilité concernant les
errata, modifications, révisions ou mises à
jour.

Les Représentants de Service qualifiés et
autorisés de Cleveland Range, LLC sont
tenus de se conformer aux mesures de
sécurité normalisées de l’industrie, y
compris, mais sans s'y limiter, les
réglementations de l'OSHA, les procédures
de  débranchement / verrouillage /
étiquetage relatives à tous les services
publics, dont l’approvisionnement en
vapeur, et les procédures de
débranchement / verrouillage / étiquetage
relatives aux équipements et/ou appareils
fonctionnant au gaz, à l’électricité et à la
vapeur.

Au cours de tout entretien d’un appareil
Cleveland Range, tous les services publics
(gaz, électricité, eau et vapeur) doivent être
FERMÉS au niveau de l’appareil et le
dispositif de fonctionnement doit être
verrouillé suivant les pratiques approuvées
de l’OSHA.

Les Représentants de Service qualifiés et
autorisés de Cleveland Range, LLC sont
tenus d’actualiser en permanence leurs
connaissances, compétences, matériel et
équipement.

Este documento está destinado para el uso
de los Representantes de Servicio
calificados y autorizados de Cleveland
Range, LLC quienes cuentan con la
experiencia y la capacitación así como el
buen conocimiento de las medidas de
seguridad y de los equipos que mantienen. 

Cleveland Range, LLC, declina toda
responsabilidad en caso de cualquier
fallecimiento, lesiones, daños al equipo o
daños a la propiedad resultantes de la
utilización, del uso indebido o de la falta de
utilización de la información provista en este
documento.

Cleveland Range, LLC se ha esforzado en
suministrar información precisa en este
documento, pero no puede garantizar que
este documento esté exento de errores y de
omisiones no intencionales.

La información contenida en este
documento podría estar sujeta a cambios
técnicos o tecnológicos, revisiones o
actualizaciones.  Cleveland Range, LLC
declina toda obligación o responsabilidad
con respecto a erratas, modificaciones,
revisiones o actualizaciones.

Los Representantes de Servicio calificados y
autorizados de Cleveland Range, LLC tienen
la obligación de seguir los procedimientos
estándar de seguridad de la industria; los
cuales incluyen pero no se limitan a los
reglamentos de la OSHA (La Administración
de la Seguridad y Salud Ocupacionales), los
procedimientos de desconexión, cierre y
etiquetado relativos a todos los servicios
públicos incluyendo el suministro de vapor y
los procedimientos de desconexión, cierre y
etiquetado para los equipos y/o aparatos
que funcionan a base de gas, electricidad o
vapor.

Cuando se esté dando servicio o
mantenimiento a un aparato de Cleveland
Range, todos los servicios públicos (gas,
electricidad, agua y vapor) deben estar
APAGADOS para el equipo en cuestión y se
debe seguir el procedimiento de cierre de
operaciones de acuerdo con las prácticas
aprobadas por la OSHA.

Los Representantes de Servicio calificados y
autorizados de Cleveland Range, LLC tienen
la obligación de actualizar constantemente
sus conocimientos, destrezas, materiales y
equipamiento.

Содержание 36-CDM-16

Страница 1: ...new information and models are released Visit our website for the latest manual ConvectionPro Steamers Part KE004033 2 C MODEL 36CGM16 36CEM16 36CSM16 36CDM16 For your future reference Model ________...

Страница 2: ...nformer aux mesures de s curit normalis es de l industrie y compris mais sans s y limiter les r glementations de l OSHA les proc dures de d branchement verrouillage tiquetage relatives tous les servic...

Страница 3: ...juste modificaci n servicio o mantenimiento puede ocasionar da os a la propiedad lesiones o muerte Lea detenidamente las instrucciones de instalacion y de operaci n antes de instalar poner a funcionar...

Страница 4: ...de presi n Keep clear of pressure relief discharge Restez l cart de la soupape de suret Permanezca alejado de la descarga de presi n Do not lean on or place objects on the equipment Ne vous penchez p...

Страница 5: ...team Generators Direct Steam Connected Steamers Kettles Installation Check 8 Gauge Pressure Reading 9 OPERATION 9 Controls and Controls Panels 9 Start up and Preheat 12 Cooking Operations 13 The Key P...

Страница 6: ...call the gas supplier from a phone away from the building Follow the gas supplier s instructions If the gas supplier cannot be reached call the fire department C Operational Safety The Operational Saf...

Страница 7: ...a qualified Cleveland Range authorized service representative BURN and SCALD HAZARD Exposure to steam condensate and hot surfaces can cause death burns and scalds To avoid injury Do NOT breathe steam...

Страница 8: ...authorized service representative Model Number________________________________________________________ Serial Number____________________________________________________________ Write the Serial Number...

Страница 9: ...combustible areas that have provisions for adequate air supply The term boiler will be used synonymously with steam generator 2 Position For proper operation and drainage the equipment must be level...

Страница 10: ...on Toe data contained in step 5 for a ld water also applies to hot water 5 Connect COLD water supply plumbing to the line strainer Never Connect hot water to the boiler water fill line strainer Consta...

Страница 11: ...s than 14 Water column Installation must be in accordance with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 1984 Installation in Canada must be in accordanc...

Страница 12: ...roughly before connecting it to the boiler To ensure an adequate volume of steam the branch steam supply line must be 3 4 inch IPS minimum Connect the inverted bucket trap to the outlet end of the ste...

Страница 13: ...ts verify that there is a 115 Volt connection at the handi box located on the left side of the base at the bottom front 8 On steam coil units the incoming steam pressure must be 35 to 50 psi Less than...

Страница 14: ...wner s and operator s for future reference Controls and Control Panels There are two steam generator control arrangements and two steamer compartment control panels available for Cleveland Range Conve...

Страница 15: ...10...

Страница 16: ...11 Control Panels Key Pad Control Panel Dial Timer Control Panel...

Страница 17: ...n Pro XVI steamer cooking compartments For accurate efficient cooking times the cook ing compartments should be preheated during startup a Close the compartment door by gently swinging it shut b Refer...

Страница 18: ...y from the steamer when first opening the door Do not look into the cooking compartment until steam has cleared Keep hands out of the cooking compartment to prevent burns 13 Manual Cooking Operation K...

Страница 19: ...he timer for 1 hour and 15 minutes Change 1 hour 60 min and 15 minutes to 75 minutes Press the following number keys in sequence 7 5 0 0 The display will read 75 00 when properly set for 1 hour and 15...

Страница 20: ...using timed or manual cooking modes optimum steam heat transfer and therefore a higher quality food product is achieved when shallow per forated uncovered pans are used Manual Cooking Operation Dial...

Страница 21: ...artment steaming cycle Use automatic mode when an exact cooking time is required Stearn cooking begins when the timer is set and automatically stops when the timer counts down to zero 1 Check that the...

Страница 22: ...ter boils away as steam When allowed to accumulate the water becomes highly mineralized which results in erratic operation lime build up corrosion and premature electric heater failures In some cases...

Страница 23: ...freely through the compartment drain openings If it does not the drain must be cleaned before using the steamer 4 To prolong door gasket life always leave compartment door ajar when not in use 5 Exter...

Страница 24: ...ed serviceman Once every three months the cold water line strainer should be cleaned Cleveland Range supports a comprehensive network of Maintenance and Repair Centers regional parts and service distr...

Страница 25: ...d Timer Settings are followed Steaming fresh vegetables on perforated pans gives best results Two to three institutional packages of frozen vegetables will fit into one 12 x 20 x 2 Cafeteria Pan ADDIT...

Страница 26: ...5 lb block peeled In Minutes Fresh Frozen 4 12 4 6 Lobster whole 1 lb 7 9 Lobster tails 8 oz defrosted butterflied Mussels in shell 2 Oysters in shell 2 4 5 6 3 4 4 6 2 4 6 8 8 10 4 6 4 5 7 4 6 4 5 10...

Страница 27: ...er and juicy and when served is the same size as the rare steak Sirloin patties chopped 8 oz Aibeye 8 oz Top butt steak 6 oz 8 oz Fllet Mignon butterflied 4 oz 6 oz 8 oz 10 oz 16 oz whole Chateaubrian...

Страница 28: ...ved descaler Electric models only Heating elements damaged See note 1 Water sensors covered by scale deposits Descale steam generator with USDA approved descaler Inoperative controls See note 1 Abnorm...

Страница 29: ...h too much food Put less food in pan Use fewer pans Voltage too low for unit See note 4 Suggested cooking times are usually listed for cooking at sea level Extend cooking times for altitudes above 250...

Страница 30: ...itchencare com To learn how Welbilt Foodservice and its leading brands can equip you visit our global web site at www welbilt com then discover the regional or local resources available to you Every n...