For Electric-Powered Steam Generators
:
Connect electric power: location and data are shown
on the specification sheet. Provide connection as required by the unit; either directly to the single
contactor, or to the terminal block (when equipped with multiple contactors). Electric supply must
match power requirements specified on the data plate inside the base cabinet. The copper wiring
must be adequate to carry the required current at the rated voltage. Separate fused disconnect
switch must be supplied and installed. The unit must be electrically grounded by the installer.
For Steam Coil Steam Generators:
Connect steam supply piping to the input side of the steam
coil. Location and pressure data are shown on the specification sheet. Incoming steam pressure
must be regulated between 35 and 45 psi. A 3/4-inch strainer equipped with a 20 mesh stainless
steel screen must be supplied and installed at the incoming steam connection point. Flush the
steam line thoroughly before connecting it to the boiler. To ensure an adequate volume of steam,
the branch steam supply line must be 3/4-inch IPS minimum. Connect the inverted bucket trap to
the outlet end of the steam coil. Fill the trap with water before installing it. A permanent 115 volt
electrical connection is required at the junction box. The junction box location is shown on the
specification sheet. The unit must be electrically grounded by the installer.
For Direct-Steam Connected Steamers/Kettles
:
Collect steam supply piping to the input side of
the line strainer. Location and pressure data are shown on the specification sheet. Flush the steam
line thoroughly before connecting it to the steamer. To ensure an adequate volume of steam, the
branch steam supply line must be 3/4-inch IPS minimum. (Direct-steam-connected kettles require
1/2-inch IPS pipe if the kettle total capacity is 20 gallons or less and 3/4-inch IPS pipe if the total
capacity exceeds 20 gallons.) A permanent 115 volt electrical connection is required at the junction
box. The junction box location is shown on the specification sheet. The unit must be electrically
grounded by the installer.