4
.
The drain line outlet discharges exhaust steam and hot condensate. Connect 1-1/2-inch IPS piping (or
larger) to
extend the drain line to a nearby open floor drain. Up to two elbows and six feet of 1-1/2-inch IPS (or
larger) exten-sion pipe should be connected to the drain termination. Drain piping extended six to twelve feet,
or
using three
elbows, should be increased to 2-inch lPS No more than two pieces of Cleveland Range
equipment
should be
connected to one common drain line. The maximum length of extension from the drain
termination
should not
exceed six feet and use no more than two elbows. The extension piping must have a
gravity flow
and vent freely to
the air. This drain outlet must be free-vented to avoid the creation of back
pressure in the
steamer cooking
Compartments. To ensure a vented drain line, DO NOT, UNDER ANY
CIRCUMSTANCES,
CONNECT THE DRAIN
OUTLET DIRECTLY TO THE FLOOR DRAIN OR SEWER LINE.
Do not run the drain
line discharge into PVC drain
piping or any other drain piping material not capable of
sustaining 180°F
operation.
Note: Direct-steam connected pressure steamers do not require
cold
water
connection
,and therefore steps 5 and
6 do not apply. Refer directly to step 7.A
kettle fill faucet, if so equipped, requires a hot and/or
cold
water connection.
Toe data contained in step
5
for a>ld water also applies to hot water.
5.
Connect COLD water supply plumbing to the line strainer. (Never Connect hot water to the boiler water fill
line
strainer.) Constant flow pressure must be maintained between 35 and 60 psi, and not experience a
pressure drop
below 35 psi when other appliances are used. If the water pressure exceeds 60 psi. a pressure
reducing valve must
be installed in the water supply plumbing to reduce the water pressure to less than 60 psi.
Locations and pressure
data are shown on the specification sheet. 1/4-inch IPS plumbing is sufficient for water
supply lines up to 20 feet in
length but water supply lines longer than 20 feet should be at least 3/8-inch IPS.
Flush water supply lines thoroughly
before connecting them to the unit. Use water which is low in total
dissolved solids content and low in gas content to
prevent internal scaling, pitting and corrosion of the steam
generator, and carry-over of minerals into the steam.
Water which is fit to drink can still contain highly
detrimental impurities.
NOTE
: If equipped with a kettle and kettle water fill swing spout, 3/8-inch (10mm) hot and/or cold water
connections
will be required at the swing spout valve.
6.
Turn on the Cold water supply to the unit. Ensure that the manual water valve, inside the base cabinet is
open.
7.
Connect the primary fuel supply in accordance with the following instructions. Location and other data are
shown
on the specification sheet
5