1 .7
MOUNTING LOCATION, TLD OUTPUT CONTACTS
SIZE HOLE FOR 1/2 INCH ELECTRICAL CONDUIT
1 /2"
AC POWER
CORD
7 of 18
A800-7425 J
Figure 5
WARNING
The following Calibration Instructions are for
use by qualified personnel only. To reduce the
risk of electric shock,
DO NOT
perform any
servicing other than that contained in the
Operating Instructions unless you are qualified
to do so.
Route the required output contact wiring from the
Tension Limit Detection Relay Card terminal block
through this conduit. See Figure 5.
3.0 ADJUSTMENTS
Check that the indicator has been wired correctly per
the installation wiring diagram and that the jumper at
2TB is set for the proper line voltage.
3.1 ANALOG METER MECHANICAL
ZERO-ADJUSTMENT
Before turning the unit on, check to see that the meter
needle is on zero. Make any required adjustments with
the small zero adjustment screw on the meter face.
3.2 ELECTRICAL ZERO-ADJUSTMENT
Switch the unit on and allow three or four minutes
warm-up time. The pilot light will indicate power is being
supplied to the indicator.
The models with the TRL feature have a zero and a
calibrate adjustment for both the left transducer and