Figure 3
WARNING
These Installation Instructions are for use by
qualified personnel only. To reduce the risk of
electric shock, do not perform any servicing
other than that contained in the Operating
Instructions unless you are qualified to do so.
CAUTION
Before making any line power connections,
verify that the 100/115/230V jumper at 2TB on
the Circuit Board Assembly is set for the
proper voltage. Refer to the following table:
The indication system shown in Figure 3 utilizes two
strain gate transducers and sums the signals in the indicator.
The Tensi-Master indicators can also be used for
cantilever, wire, and single transducer applications.
1.0 GENERAL INFORMATION
2.0 INSTALLATION
AC VOLTS
JUMPER
100
2TB-23 TO 2TB-24
115
2TB-23 TO 2TB-25
230
2TB-23 TO 2TB-26
Look in the back of the manual for the outline drawing
for mounting dimensions and the wiring diagram for
cable connections.
For indicators with terminal block connections, the ends
of the transducer cables having the shield lead are
connected to the indicator. For indicators which have
MS connectors, the ends of the transducer cables that
are marked white are connected to the indicator. For
indicator mating connectors, refer to the following table.
MATING CONNECTORS FOR INDICATORS
Содержание Cleveland-Kidder TMI
Страница 2: ...2 of 18 A800 7425 J Figure 1 1 0 GENERAL INFORMATION...
Страница 12: ...12 of 18 A800 7425 J 7 0 OUTLINE DIMENSIONS...
Страница 13: ...13 of 18 A800 7425 J 7 0 OUTLINE DIMENSIONS...
Страница 15: ...15 of 18 A800 7425 J INSTRUCTION m m A800 7425 J Page 1 of 16 8 0 INSTALLATION WIRING DIAGRAM...
Страница 16: ...16 of 18 A800 7425 J 8 0 INSTALLATION WIRING DIAGRAM...