4 of 18
A800-7425 J
Figure 2
when the tension level goes out of range and the
switching of the TLD relay.
1.0 GENERAL INFORMATION
8.
Tension Limit Detector Level Pot - For TLD
12. Jumper - This moveable jumper should be in
option only. This adjustment sets the tension level
position 7J for use with digital tension meter.
at which the TLD relay switches.
Position 6J provides a 0-10VDC tension signal
9.
Isolation Amplifier Power Cable - For isolation
amplifier option only. The cable must be connected
13. Potentiometer 5P - Adjustment for the digital
between 22TB on the isolation amplifier and 3TB
tension meter display.
on the indicator main circuit board. It supplies
power to operate the isolation amplifier.
10. Isolation Amplifier Selection Switch - For isolation
amplifier option only. Set switch to 0-10V position
for 0 to 10 VDC output, set switch to 4-20mA
position for 4-20mADC output.
11. Line Power Fuse - Replace with 3AG, 0.5A, 250
fuse only.
output.
1.5 PRINCIPLES OF OPERATION
The measurement of the actual tension in a web is made
by sensing, with strain gage transducers, the force on a
sensing roll caused by the tension in the web. The
electrical signal from the transducers is registered on the
tension indicator meter as the total tension.
Содержание Cleveland-Kidder TMI
Страница 2: ...2 of 18 A800 7425 J Figure 1 1 0 GENERAL INFORMATION...
Страница 12: ...12 of 18 A800 7425 J 7 0 OUTLINE DIMENSIONS...
Страница 13: ...13 of 18 A800 7425 J 7 0 OUTLINE DIMENSIONS...
Страница 15: ...15 of 18 A800 7425 J INSTRUCTION m m A800 7425 J Page 1 of 16 8 0 INSTALLATION WIRING DIAGRAM...
Страница 16: ...16 of 18 A800 7425 J 8 0 INSTALLATION WIRING DIAGRAM...