Unit 1, 10 Duerdin St, Clayton VIC 3168, Australia
Tel: +61 3 9239 8088 Fax: +61 3 9239 8024
E-mail: [email protected] www.clenergy.com.au
7
page
of 15
Installation Guide_PostMount 3-A for XL Panels_AU_V1.1 (January 2021)
Installation Instruction
4.3 Rectangular Tube-Master and Adjustable Tube Installation
4.3.1 Fix the Rectangular Tube-Master at Steel Cap
Assembly with M14*120 hex bolt, M14 nut, plain
washer 14, and spring washer 14. See the mark
①
.
4.3.2 Fix the Adjustable Tube at Rectangular Tube-
Master with M14*120 hex bolt , plain washer 14,
and spring washer 14, M14 nut. See the mark
②
.
4.3.3 Fix the Adjustable Tube at Steel Cap Assembly
with M14*120 hex bolt, M14 nut, plain washer 14,
and spring washer 14. See the mark
③
.
Realized the angle adjustment by position the bolt
in the differrent holes.
4.3.4 Fasten the Steel Cap Assembly to Pipe with
M14*150, M14*110 Hex Bolt, keep the Rectangular
Tube-Master parallel to the south-north by adjust the
Steel Cap Assembly.
Recommended torque for M14 bolts is 95~100 N·m.
Note:
1: Adjust the angle of the allation, the angle of the Rectangular Tube-Master with 10° (6 holes
from up to bottom corresponds to 10° to 60° tilt angle) in order to make the assembly process
run smooth.
2: Using the adjustable washer to avoid the gap between the Rectangular Tube-Master and the
Adjustable Tube. Unreliable connection is forbidden.