18
P2544PM | 2021-02
Apex Tool Group
3
EN
3.6.1
Configuring FastApps
Up to ten FastApps can be programmed. The maximum tightening time is ten seconds.
>
Fig. 3-7: Submenu – Configuring FastApps
Button
Description
Display of the selected direction of rotation.
Depending on the selected direction of rotation, one of the two symbols is displayed.
Display of the tightening strategy. Depending on the selected shutoff, one of the sym-
bols will be displayed. One torque and one angle shutoff is possible.
•
Display of the torque shutoff.
•
Display of the angle shutoff.
For a torque shutoff, enter the shut-off torque.
For an angle shutoff, enter the shut-off angle.
Once the value has been reached, the tightening process is completed. This setting
option is the same as in the menu 3.6.4 Advanced settings, page 20.
Note
If the shut-off value is entered here in the
Configuring FastApps
menu, then the follow-
ing values are calculated automatically:
Parameter
Torque shutoff
Angle shutoff
Low torque
-15% of the shut-off torque
Threshold torque
MaxTorque
+15% of the shut-off torque
Tool capacity
Minimum angle
0
-10 deg of the shut-off angle
Maximum angle
9999
+10 deg of the shut-off
angle
Threshold torque
50% of the shut-off torque
Manual input
Final speed
50
50
Speed threshold
1/4 x shut-off torque
Threshold torque
These values can be changed manually in the
menu, see 3.6.4 Advanced settings,
page 20.
Entering the threshold torque.
This button is only displayed during angle shutoff. This setting option is the same as in
the menu 3.6.4 Advanced settings, page 20.
1