27
– – –°F – – –°C
*M019 is a Message Code. See Fault Log under “ADDITIONAL SETTINGS”.
SPA BEHAVIOR
Pumps
On the Spa Screen, select a
Pump Button
once to turn the pump on or off. If left
running, the pump will turn off after a time-out period.
Circulation Pump Modes
If the system is equipped with a circ
ulation
pump, it will be configured to work
in one of three different ways:
1: The circ
ulation
pump operates continuously (24 hours) with the exception of
turning off for 30 minutes at a time when the water temperature reaches 3°F
(1.5°C) above the set temperature (most likely to happen in very hot climates).
2: The circ pump stays on continuously, regardless of water temperature.
3: A programmable circ pump will come on when the system is checking temper-
ature (polling), during filter cycles, during freeze conditions, or when another
pump is on.
The specific Circulation Mode that is used has been determined by the Manufac-
turer and cannot be changed in the field. Other device options may be available,
like Blower, Light, Mist, etc.
Filtration and Ozone
On non
circ
ulating
systems, Pump 1 low and the ozone generator will run during
filtration. On circ
ulating
systems, the ozone will generally run with the circ pump,
but can be limited to filtration cycles.
The system is factory-programmed with one filter cycle that will run in the evening
(assuming the time-of-day is properly set) when energy rates are often lower. The
filter time and duration are programmable (See “ADJUSTING FILTRATION”). A sec-
ond filter cycle can be enabled as needed.
At the start of each filter cycle, the water devices like blower, mist device (if these
exist) and other pumps will run briefly to purge the plumbing to maintain good
water quality.