Salt System with ISIS control panel.
NOTE: Anytime you add a chemical,
turn the jets on to help dissolve it
appropriately.
The control of the ISIS Top Side is
identical to the ISIS 1 controller.
The user interface is as follows:
• To activate the topside control, any of the
push button keys must be held down for the
entire Key Lockout deactivation sequence
which takes several seconds.
• If the Key Lockout has been activated and
any push button key is pressed, the three
digit Seven Segment Display will display “Loc”.
• After one second, the three digit Seven
Segment Display will display a “3” in the
center digit.
• The push button key must be held down until the three digit Seven Segment
Display decreases to “1” and the power setting is displayed, then bromine out-
put or boost can be adjusted.
• The displayed count will be displayed as quickly as in 0.75 second intervals. If
the depressed push button key is not released within five seconds after the
power setting is displayed, the Key Lockout will be reactivated preventing an
accidental increase or decrease in bromine production ( this is a precautionary
– safety feature of the ISIS TS System).
• After the power setting is displayed, the push button keys are activated and
power setting is enabled (normal error code display is also resumed). If any key
remains depressed for five seconds during the deactivated Key Lockout period,
the Key Lockout will reactivate and disable control features.
• The Key Lockout will reactivate in 20 seconds after the last operational release of
a push button key. The three digit Seven Segment Display will display “Loc” for
0.5 seconds when Key Lockout is reactivated.
• Upon reactivation of the Key Lockout, the Topside Control Seven Segment Display
will display the power setting along with any active error codes or power setting
LED displays. If the Electrode Current display feature is enabled, the Key Lockout
will not reactivate.
It may take a few hours up to a day to reach the desired level of Bromine (sanitizer).
The correct level of Bromine with the Genesis System should be between 0-1 on
the generic bromine test strip. The strips that test for the active bromine (sanitizer)
level are designed for generic bromine systems. Specifically for Genesis, if the bro-
mine level reads 2 or more (which reads ok on the test strip) then there is actually
too much pure bromine in your spa. For the Genesis system that produces a more
“pure” sanitizer (without any “fillers” or extra chemicals), the “OK” range for the bro-
mine will read between 0-1 (light green) on a common bromine test strip.
Between 0-1 on the test strip is where you want your Bromine (sanitizer) level to
remain. For continued water care, adjust the Genesis control dial as needed to
remain in the “true” ok range (0-1) and “balance” your water regularly. Continue to
test the water at least once weekly to monitor the water quality. If you do not use
LEGEND FOR ISIS CONTROLLER
“tdS”
total dissolved solids
too high.
“OE”
open element
- detects
an inadequate connection.
“SE”
shortened element
detects excessive current.
“bSt”
boost
key allows you to
boost the bromine.