18
TOPSIDE CONTROLS: TP600
TURNING ON YOUR SPA
PUMP 1
PUMP 2
LIGHT
FLIP
HEAT
LIGHT
PUMP 1 PUMP 2
WARM
COOL
PUMP 1
PUMP 2
LIGHT
FLIP
HEAT
LIGHT
PUMP 1 PUMP 2
WARM
COOL
Figure 1:
TP600 control panel, 6-button (2 pumps)
Spa Models: XS Series Signature Package, U.S./Canada/European
PUMP 1
LIGHT
FLIP
HEAT
LIGHT
PUMP 1
WARM
COOL
PUMP 1
LIGHT
FLIP
HEAT
LIGHT
PUMP 1
WARM
COOL
Start Up
When the GFCI for the spa is switched on to supply power, a startup
sequence of numbers will appear on the display.
If no button is pressed,
LINK
will appear after the startup sequence. Press any button to link the
panel with the system.
The spa will then enter Priming Mode
.
The display
will read ‘RUN PUMPS PURG AIR’. Press the
Pump
Button(s) to turn the
pumps on and off to verify that all the air is purged from the plumbing,
particularly the plumbing associated with the heater. The Light Button
turns the circulation pump on an off during Priming Mode. Priming
Mode will end automatically
after
4 minutes. Pressing a Temperature
Button
(Cool or Warm)
will exit Priming Mode manually. When
Priming
Mode ends, the circulation pump will start
. However, the temperature will
not show for a few m
inutes
. Once the water temperature is recognized by the
system, and if it is below the Set Temperature, the heater will start
heating
your spa water until the
Set Temperature
is reached
.
Basic Operation
The Up
(Warm)
and Down
(Cool)
buttons are often referred to as Temperature
Button
(
s
)
. Some panels only have a single
Temperature Button
.
Press a Temperature Button once and the current Set Temperature will
flash on the LCD. The Set Temperature and the actual water
temperature are often different. While the numbers are flashing, press a
Temperature Button
again to change the Set Temperature. Press
and
hold for
faster adjustment. After the new Set Temperature stops flashing
,
the
actual temperature is displayed again and the new Set Temperature is
programmed. The spa will now heat to the new Set Temperature as
needed.
The Light Button turns the Spa Light on and off and is also used in
conjunctions
with the
Temperature Button(s)
to navigate the system
menus.
Figure 2: