AG-100, AG-200, AG-300 & AG-400

Installation & Operation Manual

Electronic Lime Scale Control System

115/230 VAC (Auto Selected)

AG-300 for pipe sizes 

up to 3" (non-ferrous)

AG-400 for pipe sizes 

up to 4" (non-ferrous)

AG-100 for pipe sizes 

up to 1 ½" (non-ferrous)

AG-200 for pipe sizes 

up to 2" (non-ferrous)

7/14

Electronic Lime Scale Control System

for Agriculture Applications

Содержание SCALEBLASTER AG-100

Страница 1: ... Control System 115 230 VAC Auto Selected AG 300 for pipe sizes up to 3 non ferrous AG 400 for pipe sizes up to 4 non ferrous AG 100 for pipe sizes up to 1 non ferrous AG 200 for pipe sizes up to 2 non ferrous 7 14 Electronic Lime Scale Control System for Agriculture Applications ...

Страница 2: ...ontheoutsideof theshippingbox If the malfunction or failure is a result of defects covered by this warranty ClearwaterEnviroTech will repair the product or replace it andreturnittothepurchaser Afteraperiodof fiveyears asmalllaborandpartschargewilloccur This warranty is limited to the original retail purchaser and is not transferable This warranty does not cover damage due to accidents abuse tamper...

Страница 3: ...AG 200 AG 300 AG 400 signal wire length to be determined by specific application pipe size and pipe material 3 Long nylon cable ties 5 or 3 5 for the AG 100 or 3 for the AG 300 AG 400 These ties aid in securing the cable to the pipe 4 Warranty Card along with this Installation Operations Manual 5 Shipping Box Please save the foam inserts and shipping box it is made to protect the descaler during t...

Страница 4: ...tlet This signal cable must be within 10 feet of the control box no matter what G commercial model i At least 6 of straight pipe before and after coil Wrap coil tightly See chart for number of wraps At least 6 of straight pipe before and after coil Tie wrap Tie wrap Power cable is 5 long If required use a 16 awg extension cord of no more than 25 Power source 115VAC or 230VAC unit auto switches Coi...

Страница 5: ...ndow and other inside components The power unit should be mounted on a wall or solid surface within 5 feet from an electrical outlet and within ten 10 feet from the pipe in which the signal cable will be wrapped If the power unit has to be more than 10 feet of where the signal cable will be wrapped you should contact your dealer or call Clearwater Enviro Tech for assistance The ScaleBlasterAG comm...

Страница 6: ...he bare wires together to get rid of any stray strands 2 Unscrew one of the two receptacle posts located on the ScaleBlaster power box computer It does not matter if you use the red or black receptacle first 3 Then insert the spliced wire of the signal cable end completely through the opening Tighten the receptacle post as much as possible 4 It is very important you have a tight connection and tha...

Страница 7: ...MOUNT OF COILS SUGGESTED Over wrapping can significantly decrease the power of the signal If you are unable to obtain correct number of wraps due to straight pipe issues of not giving you enough space the minimum number of wraps the unit requires is at least 30 wraps AS PREVIOUSLY NOTED MAKE SURE THE CONTROL BOX IS MOUNTED AS CLOSE AS POSSIBLE TO WHERE THE SIGNAL CAB E IS WRAPPED ON THE PIPE THE M...

Страница 8: ...LY If there is an error or the coil just isn t yet attached the screen to the left will appear If the coil is connected and the message to the left is present then contact your dealer or Clearwater Enviro Tech for help AG 300 AG 400 This screen to the right will appear if the internal temperature reaches 180 degrees Fahrenheit At this point the unit will shut down until the temperature subsides Th...