F.) Powering up the Control Box / Computer

G.) LCD Indicator Screen

1.) The unit will work automatically on either 115 or 230 VAC, however the unit has a 115 

VAC power plug on the end.  You may simply plug this into a 115VAC outlet. Since 

electrical outlets vary worldwide, or if you need 230VAC, the power cord plug may not 

match your outlet type.  In this case, it must be replaced with the proper plug by a 

licensed electrician.

2.) Plug the power cord into the outlet. 

3.) The unit should stay on 24 hours a day.

4.) Monitor the LCD screen from time to time to be sure of continuous operation.

OPERATIONAL

ERROR MODE

The Scanning Frequency Screen to the left indicates the unit is functioning correctly and is 

sweeping the full frequency range of the calcium resonance. When the 

AG-300 and AG-400

 

are operating normally they will alternate between the two screens shown. 

The screen to the right will intermittently show the 

coil output status in percent and the internal system 

temperature. 

NOTE: AG-300 and AG-400 ONLY

If there is an error (or  the coil just isn't yet attached)  the screen to the left will appear. 

If the coil is connected and the message to the left is present, then contact your dealer 

or 

Clearwater Enviro Tech

 for help.

 (AG-300 & AG-400)

This screen to the right will appear if the internal temperature reaches 180 degrees 

Fahrenheit. At this point the unit will shut down until the temperature subsides.  This 

can happen if you inadvertently short out the coil output for extended periods of time or 

mount the unit in direct sunlight. 

NOTE: AG-300 and AG-400 ONLY

Manufactured by

8767 115th Ave. N. • Largo, FL  33773

Phone: 800-756-7946 or 727-562-5186 • Fax: 727-562-5187

clearwaterenviro.com

MADE IN THE U.S.A.

Figure A

Figure B

Power

Indicator

Signal

Indicators

The LED light on the front panel (far right) should light up on the 

AG-100 & AG-200

 

after being plugged in.

Operation of the 

AG-100 & AG-200

 system can be confirmed by observing the 

illumination of the LED indicator located on the face of the power unit. Power on - green 

light on far right side will stay lit 

(Figure A)

. When pipe is wrapped and unit is turned on 

the far right light will stay lit and the other lights will oscillate back and forth 

(Figure B)

.

Содержание SCALEBLASTER AG-100

Страница 1: ... Control System 115 230 VAC Auto Selected AG 300 for pipe sizes up to 3 non ferrous AG 400 for pipe sizes up to 4 non ferrous AG 100 for pipe sizes up to 1 non ferrous AG 200 for pipe sizes up to 2 non ferrous 7 14 Electronic Lime Scale Control System for Agriculture Applications ...

Страница 2: ...ontheoutsideof theshippingbox If the malfunction or failure is a result of defects covered by this warranty ClearwaterEnviroTech will repair the product or replace it andreturnittothepurchaser Afteraperiodof fiveyears asmalllaborandpartschargewilloccur This warranty is limited to the original retail purchaser and is not transferable This warranty does not cover damage due to accidents abuse tamper...

Страница 3: ...AG 200 AG 300 AG 400 signal wire length to be determined by specific application pipe size and pipe material 3 Long nylon cable ties 5 or 3 5 for the AG 100 or 3 for the AG 300 AG 400 These ties aid in securing the cable to the pipe 4 Warranty Card along with this Installation Operations Manual 5 Shipping Box Please save the foam inserts and shipping box it is made to protect the descaler during t...

Страница 4: ...tlet This signal cable must be within 10 feet of the control box no matter what G commercial model i At least 6 of straight pipe before and after coil Wrap coil tightly See chart for number of wraps At least 6 of straight pipe before and after coil Tie wrap Tie wrap Power cable is 5 long If required use a 16 awg extension cord of no more than 25 Power source 115VAC or 230VAC unit auto switches Coi...

Страница 5: ...ndow and other inside components The power unit should be mounted on a wall or solid surface within 5 feet from an electrical outlet and within ten 10 feet from the pipe in which the signal cable will be wrapped If the power unit has to be more than 10 feet of where the signal cable will be wrapped you should contact your dealer or call Clearwater Enviro Tech for assistance The ScaleBlasterAG comm...

Страница 6: ...he bare wires together to get rid of any stray strands 2 Unscrew one of the two receptacle posts located on the ScaleBlaster power box computer It does not matter if you use the red or black receptacle first 3 Then insert the spliced wire of the signal cable end completely through the opening Tighten the receptacle post as much as possible 4 It is very important you have a tight connection and tha...

Страница 7: ...MOUNT OF COILS SUGGESTED Over wrapping can significantly decrease the power of the signal If you are unable to obtain correct number of wraps due to straight pipe issues of not giving you enough space the minimum number of wraps the unit requires is at least 30 wraps AS PREVIOUSLY NOTED MAKE SURE THE CONTROL BOX IS MOUNTED AS CLOSE AS POSSIBLE TO WHERE THE SIGNAL CAB E IS WRAPPED ON THE PIPE THE M...

Страница 8: ...LY If there is an error or the coil just isn t yet attached the screen to the left will appear If the coil is connected and the message to the left is present then contact your dealer or Clearwater Enviro Tech for help AG 300 AG 400 This screen to the right will appear if the internal temperature reaches 180 degrees Fahrenheit At this point the unit will shut down until the temperature subsides Th...