CLEARSPAN
™
POLY BUILDINGS
8
Revision date: 12.08.15
ATTACHING RAFTER FEET TO CONCRETE WALL
Additional materials required to secure rafter feet to concrete are not included and must be purchased by customer.
Materials and rafter foot shown in the following diagrams differs from that included with building.
Use the following information to determine anchor bolt that best applies.
1. See next pages to properly position mounting plate. Using plate as a template, drill holes into the concrete pony wall
or pier according to anchor bolt size.
IMPORTANT:
DO NOT over-drill hole.
Wedge anchor bolt will not work properly
if hole is too deep. Mounting plate shown
differs from actual plate. Installation is
same.
2. Insert anchor bolt into one drilled hole. Firmly tap with
a hammer to secure wedge anchor into concrete.
NOTE:
Depending on wedge anchor bolt, verify the
washer and nut are attached
before
driving anchor
bolt. Striking bolt may cause thread damage and
prevent nut installation after bolt is set.
3. Tighten nut.
4. Repeat for each anchor bolt until mounting plate is
adequately secured to concrete base.
5. Repeat steps to secure remaining plates.
Length of Anchor Bolt equals (=):
Thickness of material to be fastened
+plus minimum embedment (see manufacturer recommendation)
+plus 1" for nut and washer application.
Sample
wedge
anchor bolt