Appendices
~ Appendix E: Serial Commands
128
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
MINIT - Modem Initialization String
This command sets/reports the modem initialization string of the serial port when in
modem mode.
Command form: DEVICE MINIT [String]
Argument details
Name
Description
Device
0–7 or * to select all units
MINIT
Command form
String
1-80 characters (select string characters to be sent to the modem
when the unit is initialized
CLEAR = clears the modem initialization string
Null = Current string
Example:
#76 MINIT ATZ
On XAP 400 unit 6 (
#76
), the modem initialization
string (
MINIT
) is
ATZ
.
MINMAX - Minimum and Maximum Gain Setting
This command changes or reports back the minimum and maximum gain setting for
an input, output or assignable processing block.
Command form: DEVICE
MINMAX
<Channel> <Group> [Minimum] [Maximum]
Argument details
Name
Description
Device
0–7 or * to select all units
MINMAX
Command form
Channel
See Groups and Channels
Group
I, O, M, P, L
Minimum
-65.00 to 20.00, Null to return current settings
Maximum
-65.00 – 20.00
Example:
#75 MINMAX 2 M -12 10
On XAP 400 unit 5 (
#75
), the minimum
and maximum (
MINMAX
) relative gain settings for mic (
M
) channel
2
are
-12
dB
and
10
dB respectively.
Содержание XAP 400
Страница 1: ...Audio Products XAP 400 Audio Conferencing System Installation Operation Manual...
Страница 2: ...XAP 400 Audio Conferencing System Installation Operation Manual...
Страница 27: ...20 Technical Services Group 1 800 283 5936 USA 1 801 974 3760...
Страница 99: ...92 Technical Services Group 1 800 283 5936 USA 1 801 974 3760...
Страница 172: ...165 Technical Services Group 1 800 283 5936 USA 1 801 974 3760...
Страница 173: ......