143
Appendices
~ Appendix E: Serial Commands
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
TOUT - Time Out Select
This command selects/reports the inactivity time out before returning to the unit title
screen.
Command form: DEVICE
TOUT
[Value]
Argument details
Name
Description
Device
0–7 or * to select all units
TOUT
Command
Value
0 = Off, 1–15 (select time out in minutes)
Null = Current mode
Example:
#72 TOUT 5
On XAP 400 unit 2 (
#72
), the front panel of the unit will
time out (
TOUT
) after
5
minutes.
UID - Unit ID
This command reports the unit ID. This command is read only.
Command form: DEVICE
UID
[Value]
Argument details
Name
Description
Units
Device
0–7 or * to select all units
UID
Command
Value
Null to return value
Hexadecimal
Example:
#73 UID B465F991
The unit ID number (
UID
) received from XAP 400
unit 3 (
#73
), is
B456F991
.
VER - Version
This command reports the firmware version of the unit. This command is read only.
Command form: DEVICE
VER
[Value]
Argument details
Name
Description
Device
0–7 or * to select all units
VER
Command
Value
Null to return value
Example:
#74 VER 1.0.0
The version of the firmware (
VER
) programmed into
XAP 400 unit 4 (
#74
), is
1.0.0
.
Содержание XAP 400
Страница 1: ...Audio Products XAP 400 Audio Conferencing System Installation Operation Manual...
Страница 2: ...XAP 400 Audio Conferencing System Installation Operation Manual...
Страница 27: ...20 Technical Services Group 1 800 283 5936 USA 1 801 974 3760...
Страница 99: ...92 Technical Services Group 1 800 283 5936 USA 1 801 974 3760...
Страница 172: ...165 Technical Services Group 1 800 283 5936 USA 1 801 974 3760...
Страница 173: ......