Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
COMPRESS - Compressor Adjust
This command selects/reports the setting of the compressor on processing channels.
Command form
DEVICE
COMPRESS
<Channel> [Threshold] [Ratio] [Attack]
[Release] [Gain]
Argument details
Name
Description
Units
Device
0–7 or * to select all units
COMPRESS
Command form
Channel
Range A–D (selects processing channel)
Threshold
-30 to 20, Null to return current value
dB
Ratio
1 to 20
Attack
0.00 to 100.00 (select in .5ms intervals)
ms
Release
100 to 2000 (select in 5ms intervals)
ms
Gain
0.00 to 20.00
dB
Example:
#71 COMPRESS A 6 5 25 250 3
On XAP 400 unit 1 (
#71
), the
compression (
COMPRESS
) within processing channel
A
is set to have a threshold
of
6
dB, a ratio of 5:1 (
5
), an attack time of
25
ms, a release time of
250
ms, and a
gain of
3
dB.
COMPSEL - Compression Select
This command selects/reports the compressor activation of each assignable
processing channel.
Command form:
DEVICE
COMPSEL
<Channel> [Value]
Argument details
Name
Description
Device
0–7 or * to select all units
COMPSEL
Command form
Channel
Range A–D (selects processing channel)
Value
0 = Off, 1 = On, 2 = Toggle, Null returns current state
Example:
#70 COMPSEL A 1
On XAP 400 unit 0 (
#70
), the compression
(
COMPSEL
) within processing channel
A
is set on (
1
).
Содержание XAP 400
Страница 1: ...Audio Products XAP 400 Audio Conferencing System Installation Operation Manual...
Страница 2: ...XAP 400 Audio Conferencing System Installation Operation Manual...
Страница 27: ...20 Technical Services Group 1 800 283 5936 USA 1 801 974 3760...
Страница 99: ...92 Technical Services Group 1 800 283 5936 USA 1 801 974 3760...
Страница 172: ...165 Technical Services Group 1 800 283 5936 USA 1 801 974 3760...
Страница 173: ......