3 - 1 1
E F - 1 M I N T E R F A C E
6. Lift off the cover.
7. Make the necessary adjustments of jumpers P3 and P4 (shown in the following table).
To set a jumper to the closed position, plug it onto both pins. To set a jumper to the
open position, plug it onto only one of the pins.
Table 2: P3 and P4 jumper settings
8. For reassembly, reverse steps 1 through 6.
NOTE
: The potentiometer (R13) is used to factory tune the 20-kHz call-signal detection
circuitry. It should be adjusted only by qualified personnel.
BAUD 1
BAUD 2
RATE
Open
Open 19.2
kBaud
Closed Open 9.6
kBaud
Open Closed
4.8
kBaud
Closed Closed 2.4
kBaud
Make the necessary
adjustments of jumpers
P3 and P4.