3 - 6
LEVELS
EF-1M front-panel controls affect the following “listen levels”: the sidetone and volume
at the users’ stations or beltpacks; the
receive
level of the local EF-1M; and the
send
level of
the remote EF-1M.
Adjust the PL send and receive levels as appropriate for the external PL system and
listening conditions. The controls will typically be between 10 o’clock and 2 o’clock,
roughly in the 0 dBV range at the 4-wire interface. If different intercom brands are used
on opposite ends of a pair of EF-1M units (RTS and Clear-Com for example), the
controls may need to be adjusted outside of the normal range. Otherwise, more extreme
settings could indicate a problem elsewhere in the system.
Level settings will differ slightly if the EF-1M is used with RTS-TW intercoms, as the
nominal audio levels for that system are slightly higher than Clear-Com or compatible
systems (about 4-8 dB). RTS and Clear-Com may be freely mixed on a channel,
including call signaling, though the maximum number of EF-1M units able to share a
channel may be reduced. RTS levels and call signals are selected by jumpering together
pins 8 and 15 of the DB-15 connector or by setting mode-switch 2 to ON.
Adjust the PL send and
receive levels as
appropriate.