8
DWS - Series | Version 1.03
Type plate
4
Type plate
Fig. 2: Type plate DWS 1105
5
Technical Data
6
Transport, packaging, storage
6.1 Delivery
Check the water pump on delivery for any visible trans-
portation damage. If you notice any damage to the de-
vice please report this immediately to the carrier or
dealer.
6.2 Transport
During transport, the water pump must be well secured
so that it can not tip over.
6.3 Packaging
All used packaging materials and packaging aids are
recyclable and should be taken to a materials recycling
depot to be disposed of.
The delivery packaging is made of cardboard, so
please dispose carefully by having it chopped up and
given to the recycling collection.
The film is made of polyethylene (PE) and the cushioned
parts of polystyrene (PS). Deliver these substances to a
collection point for recyclable materials or to the waste
disposal company which looks after your region.
6.4 Storage
The House water system should be stored in a dry, frost-
free environment.
Water pumps must not be stacked on top of each other.
Also, no other items may be parked on it.
Step1: Turn off the water pump and drain completely.
Wipe all accessible surfaces and let the water
pump dry.
Step 2: Disconnect the suction and discharge lines from
the pump and store in a dry and frost-free place
(at least 5 ° C).
Model
DWS 1105
DWS 1105 P
Length
500 mm
492 mm
Width / Depth
285 mm
274 mm
Height
620 mm
521
Weight
16 kg
16,2 kg
Feeding height max.
46 m
46 m
Flow rate
76 l/min
76 l/min
Feed pressure
4,6 bar
4,6 bar
Inlet / outlet Ø
G 1“
G 1“
Inlet / outlet thread
1“
1“
Suction height
8 m
8 m
Engine speed
2850 min¯¹
2850 min¯¹
Engine power
1100 W
1100 W
Cooling
Air cooling
Air cooling
Sound pressure
level
82 dB
88 dB
Running time
at 75% Load
4000 Std.
4000 Std.
Max. Water
Temperature
35 °C
35 °C
Length of cable
1,5 m
1,5 m
Water tank capacity
24 l
19 l
ATTENTION!
Allow the water pump to cool completely and drain
completely from water.
The water pump may only be transported upright.
ATTENTION!
Risk of frost: If the electric pump has to be switched
off below 0 ° C, it must be ensured that there is no
liquid left in the pump. This will avoid damaging
parts of the electric pump.