background image

 

25

Water Pumps | Version 1.02

Declaration of Conformity

15 Declaration of Conformity

According to Machinery Directive 2006/42/EC, Annex II 1.A 

Manufacturer / distributor: 

Stürmer Maschinen GmbH
Dr.-Robert-Pfleger-Str. 26
D-96103 Hallstadt

hereby declares that the following product

Product Category: 

Cleancraft® Sauggeräte

Machine type:

Water pump 

Designation of the machine:

Item number

SCWP 7514

7520100

SCWP 10013

7520105

SDWP 7514

7520200

SDWP 10020

7520205

SPWP 1107

7520300

Serial number:

____________________

Year of manufacture:

20_________

complies with all relevant provisions of the above mentioned directive as well as the other applied directives (below) - 
including their applicable modifications at the time of the declaration.

This is to certify that the devices listed above comply with all the provisions of Annex I to Council Directive 2014/30 / EU.

Relevant EU Directives:

Following standards where applied:

EN 55014-1:2006+Al+A2

Electromagnetic compatibility - Requirements for household appliances, electric 
tools and similar apparatus - Part 1: Emission (CISPR 14-1:2005 + A1:2008 +  
Cor. :2009 + A2:2011); German version EN 55014-1:2006 + A1:2009 + A2:2011

EN 61000-3-2:2014

 Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic 
current emissions (equipment input current <= 16 A per phase) (IEC 61000-3-
2:2014); German version EN 61000-3-2:2014

EN 61000-3-3:2013

Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage 
changes, voltage fluctuations and flicker in public low-voltage supply systems, 
for equipment with rated current <= 16 A per phase and not subject to 
conditional connection (IEC 61000-3-3:2013); German version EN 61000-3-
3:2013

Responsible for documentation:

Kilian Stürmer, Stürmer Maschinen GmbH, 
Dr.-Robert-Pfleger-Str. 26, D-96103 Hallstadt

Hallstadt, 22.01.2018

______________________
Kilian Stürmer

Manager

Содержание 7520100

Страница 1: ...W ATER P UMPS Water pump SCWP 10013 Operating Instructions SCWP 7514 SCWP 10013 SDWP 7514 SDWP 10020 SDWP 7514 SDWP 10020 SCWP 7514 SPWP 1107 SPWP 1107...

Страница 2: ...yright 3 1 2 Customer service 3 1 3 Limitation of liability 3 2 Safety 3 2 1 Symbol explanation 3 2 2 Obligations of the operating company 4 2 3 Requirements to staff 4 2 4 Personal protective equipme...

Страница 3: ...r maschinen de We are always interested in valuable experience and knowledge gained from using the application which then could be shared and be valuable to develop our products even further 1 3 Limit...

Страница 4: ...od this manual Furthermore she must instruct the staff in regular intervals and in form them about the hazards The operator must provide the necessary protec tive equipment to the staff and order the...

Страница 5: ...the machine which are indicated in the individual paragraphs of these instructions The personal protective equipment is explained in the following paragraph 2 5 General safety regulations Please note...

Страница 6: ...temperature is lower than 4 C or the pump is not used for a long time drain the piping system to prevent ice from forming in the pump chamber ATTENTION Place the cable so that it can not be sucked in...

Страница 7: ...tact with parts and high voltage direct contact or with parts that are under high voltage due to a defect in the device in direct contact 4 Type plate Fig 2 Type plate SCWP 7514 ATTENTION Any change o...

Страница 8: ...e head max m 9 11 5 8 10 5 42 Flow rate l min 233 216 233 325 116 Feed pressure bar Inlet outlet threat Inlet Outlet mm 25 32 25 32 25 32 38 1 25 4 Suction height m 7 7 7 7 7 Grain size max mm 5 5 30...

Страница 9: ...ed on top of each other Also no other items may be parked on it Step1 Turn off the water pump and drain completely Wipe all accessible surfaces and let the water pump dry Step 2 Disconnect the suction...

Страница 10: ...as those that occur in the sew ers or rainwater are pumped Because of its compact shape and good operability the electric pump can be used as a portable suction pump for gardening or other normal con...

Страница 11: ...fting or mounting of a rope SPWP 1107 On certain models there is an outlet on the contact sur face between the pump body and the head cover It is a normal phenomenon for an electric pump that it re le...

Страница 12: ...iderable damage It is therefore essen tial to seal the threaded parts of the cables with each other and the connection to the pump with Teflon tape Only the use of sealing material such as Teflon tape...

Страница 13: ...l connection must be equipped with a high sensitive fault current circuit breaker RCCB 30 mA ATTENTION Only use an extension cable whose cross section and rubber sheathing correspond at least to the c...

Страница 14: ...the disconnected water pump Always check the supply cable for damage such as cracks or signs of aging If necessary replace the cable before further use ATTENTION The replacement of a defective power c...

Страница 15: ...the pump without pumping water must be avoided as lack of water will cause the pump to overheat This can lead to considerable damage to the device In addition there is very hot water in the system so...

Страница 16: ...hat electrical devices contain a variety of recyclable materials as well as environmentally harmful components You contributes to that these components are disposed of separately and properly In case...

Страница 17: ...e pump sucks in air B The pump runs continuously A Make sure the water supply water level is high enough When submerging immerse the pump in a slight angle B Set the float switch correctly Despite the...

Страница 18: ...SCWP 7514 must be ordered The stator housing has the number 38 in the spare parts drawing 1 Type of device Water pump SCWP 7514 Item number 7520100 Drawing number 1 Position number 38 The order numbe...

Страница 19: ...e parts drawing In case of service the following drawing shall help to identify the necessary spare parts If necessary send a copy of the parts drawing with the marked components to your authorised de...

Страница 20: ...20 Water Pumps Version 1 02 Spare parts Fig 14 Spare parts drawing 2 Model SCWP 10013...

Страница 21: ...Spare parts Water Pumps Version 1 02 21 Fig 15 Spare parts drawing 3 Model SDWP 7514...

Страница 22: ...22 Water Pumps Version 1 02 Spare parts Fig 16 Spare parts drawing 4 Model SDWP 10020...

Страница 23: ...Spare parts Water Pumps Version 1 02 23 Fig 17 Spare parts drawing 5 Model SPWP 1107...

Страница 24: ...24 Water Pumps Version 1 02 Electrical wiring diagram 14 Electrical wiring diagram Fig 18 Electrical wiring diagram of the Model SCWP 7514 SCWP 10013 SDWP 7514 SDWP 10020 SPWP 1107...

Страница 25: ...ex I to Council Directive 2014 30 EU Relevant EU Directives Following standards where applied EN 55014 1 2006 Al A2 Electromagnetic compatibility Requirements for household appliances electric tools a...

Страница 26: ...www cleancraft de...

Отзывы: