background image

16

Water Pumps | Version 1.02

Disturbances, possible causes and measures

11.2 Maintenance and repair

For the pump to work perfectly at all times, regular main-
tenance is required. This also applies if the pump is 
used under severe conditions but does not run for a 
long time (e.g. when used in wells).

Yearly maintenance:

- Check the pump housing and the chords for damage.
- Remove stubborn dirt.
- Rinse the inside of the pump by placing it in a con-
tainer filled with clear water and turn it on briefly. 
(Only with model SCWP 10013)
- Rinse the pump with clear water. 

If the water pump does not work properly, contact a 
dealer or our customer service. The contact details can 
be found in chapter 1.2 Customer Service.

All protection and safety equipment must be reinstalled 
immediately after completion of repair and maintenance 
work.

Regular maintenance and careful care reduce the risk of 
possible malfunctions and help extend the life of your 
device.

11.3 Disposal, recycling of used devices

Please take care in your own interest and in the interest 
of the environment that all component parts of the ma-
chine are only disposed of in the intended and permit-
ted way. 

11.4 Decommissioning

Immediately decommission disused machines in order 
to avoid later misuse and endangering of the environ-
ment or personal safety.

- Eliminate all environmentally hazardous operating 
materials from the used device.
- If required, disassemble the machine into easy-to-
handle and usable components and parts.

- Dispose of machine components and operating 
materials by the disposal channels provided.

11.5 Waste disposal of electric equipment

Please note that electrical devices contain a variety of 
recyclable materials as well as environmentally harmful 
components. 

You contributes to that these components are disposed 
of separately and properly. In case of doubt, please 
contact your municipal waste disposal. As necessary, a 
specialized waste disposal company can help be used 
for the treatment. 

11.6 Disposal of lubricants

Please pay attention to an environmentally friendly dis-
posal of the used coolants and lubricants.

Observe the disposal instructions of your municipal dis-
posal companies.

Disposal notes for used lubricants are available from the 
manufacturer of the lubricants. If necessary, request the 
product-specific data sheets.

12 Disturbances, possible causes and 

measures

ATTENTION!

Maintenance and repairs must always be carried out 
by qualified personnel; Any damaged parts can only 
be replaced by original spare parts.
A damaged pump must be repaired professionally.
Do not try to repair the pump yourself.
If repairs to electrical parts are necessary, please 
contact your local dealer.
Make sure the pump is off before performing any 
maintenance or repair.

ATTENTION!

If one of the following errors occurs, immediately 
stop working with the water pump.
Before you begin troubleshooting, turn off the water 
pump and unplug the power cord. Otherwise it 
could lead to serious injuries.
All repairs or replacement work may only be carried 
out by qualified and trained specialist personnel.

NOTE!

If you can not solve the problems with your water 
pump yourself, then please contact your nearest 
CLEANCRAFT dealer. Please write down the follow-
ing information from the water pump or the operating 
instructions in advance to help you with your problem 
in the best possible way. 
- Model name of the device
- Serial number of the device 
- Construction year
- Exact error description 

Содержание 7520100

Страница 1: ...W ATER P UMPS Water pump SCWP 10013 Operating Instructions SCWP 7514 SCWP 10013 SDWP 7514 SDWP 10020 SDWP 7514 SDWP 10020 SCWP 7514 SPWP 1107 SPWP 1107...

Страница 2: ...yright 3 1 2 Customer service 3 1 3 Limitation of liability 3 2 Safety 3 2 1 Symbol explanation 3 2 2 Obligations of the operating company 4 2 3 Requirements to staff 4 2 4 Personal protective equipme...

Страница 3: ...r maschinen de We are always interested in valuable experience and knowledge gained from using the application which then could be shared and be valuable to develop our products even further 1 3 Limit...

Страница 4: ...od this manual Furthermore she must instruct the staff in regular intervals and in form them about the hazards The operator must provide the necessary protec tive equipment to the staff and order the...

Страница 5: ...the machine which are indicated in the individual paragraphs of these instructions The personal protective equipment is explained in the following paragraph 2 5 General safety regulations Please note...

Страница 6: ...temperature is lower than 4 C or the pump is not used for a long time drain the piping system to prevent ice from forming in the pump chamber ATTENTION Place the cable so that it can not be sucked in...

Страница 7: ...tact with parts and high voltage direct contact or with parts that are under high voltage due to a defect in the device in direct contact 4 Type plate Fig 2 Type plate SCWP 7514 ATTENTION Any change o...

Страница 8: ...e head max m 9 11 5 8 10 5 42 Flow rate l min 233 216 233 325 116 Feed pressure bar Inlet outlet threat Inlet Outlet mm 25 32 25 32 25 32 38 1 25 4 Suction height m 7 7 7 7 7 Grain size max mm 5 5 30...

Страница 9: ...ed on top of each other Also no other items may be parked on it Step1 Turn off the water pump and drain completely Wipe all accessible surfaces and let the water pump dry Step 2 Disconnect the suction...

Страница 10: ...as those that occur in the sew ers or rainwater are pumped Because of its compact shape and good operability the electric pump can be used as a portable suction pump for gardening or other normal con...

Страница 11: ...fting or mounting of a rope SPWP 1107 On certain models there is an outlet on the contact sur face between the pump body and the head cover It is a normal phenomenon for an electric pump that it re le...

Страница 12: ...iderable damage It is therefore essen tial to seal the threaded parts of the cables with each other and the connection to the pump with Teflon tape Only the use of sealing material such as Teflon tape...

Страница 13: ...l connection must be equipped with a high sensitive fault current circuit breaker RCCB 30 mA ATTENTION Only use an extension cable whose cross section and rubber sheathing correspond at least to the c...

Страница 14: ...the disconnected water pump Always check the supply cable for damage such as cracks or signs of aging If necessary replace the cable before further use ATTENTION The replacement of a defective power c...

Страница 15: ...the pump without pumping water must be avoided as lack of water will cause the pump to overheat This can lead to considerable damage to the device In addition there is very hot water in the system so...

Страница 16: ...hat electrical devices contain a variety of recyclable materials as well as environmentally harmful components You contributes to that these components are disposed of separately and properly In case...

Страница 17: ...e pump sucks in air B The pump runs continuously A Make sure the water supply water level is high enough When submerging immerse the pump in a slight angle B Set the float switch correctly Despite the...

Страница 18: ...SCWP 7514 must be ordered The stator housing has the number 38 in the spare parts drawing 1 Type of device Water pump SCWP 7514 Item number 7520100 Drawing number 1 Position number 38 The order numbe...

Страница 19: ...e parts drawing In case of service the following drawing shall help to identify the necessary spare parts If necessary send a copy of the parts drawing with the marked components to your authorised de...

Страница 20: ...20 Water Pumps Version 1 02 Spare parts Fig 14 Spare parts drawing 2 Model SCWP 10013...

Страница 21: ...Spare parts Water Pumps Version 1 02 21 Fig 15 Spare parts drawing 3 Model SDWP 7514...

Страница 22: ...22 Water Pumps Version 1 02 Spare parts Fig 16 Spare parts drawing 4 Model SDWP 10020...

Страница 23: ...Spare parts Water Pumps Version 1 02 23 Fig 17 Spare parts drawing 5 Model SPWP 1107...

Страница 24: ...24 Water Pumps Version 1 02 Electrical wiring diagram 14 Electrical wiring diagram Fig 18 Electrical wiring diagram of the Model SCWP 7514 SCWP 10013 SDWP 7514 SDWP 10020 SPWP 1107...

Страница 25: ...ex I to Council Directive 2014 30 EU Relevant EU Directives Following standards where applied EN 55014 1 2006 Al A2 Electromagnetic compatibility Requirements for household appliances electric tools a...

Страница 26: ...www cleancraft de...

Отзывы: