Page 4
C850P (only)
•
Flexible waste hose must be securely attached to
the waste outlet elbow on the rear of the machine.
•
The waste hose must flow down from the waste
outlet elbow to the drain.
•
Diameter
1
¼
” (35mm) standpipe required, must be
lower than the baseline of the appliance
•
C850P standpipe must be a minimum of 3” (75mm)
below the baseline of the appliance.
•
Hose to be a close / tight fit into the drain pipe to
reduce odors from the drain system
4.1.2 Detergent / Soap prime :
The detergent / soap pump system on these appliances are self priming.
4.1.3 Chemical dosage :
Chemical doses are pre-set to the following nominal values, however, these values should be
calibrated to suit individual sites requirements
4.1.1 Rinse aid prime :
•
Switch machine ON and allow to fill
•
There are two prime switches on the
machine one on the front lower panel
and the other inside the machine,
Classeq would recommend that the
external switch is used for priming the
chemical.
•
Depress and hold switch.
•
To fully prime, this will take approx 1
½
minutes (90 seconds).
4.1 Rinse aid & detergent :
Ensure PVC chemical hoses are attached correctly to the individual chemical pumps
(pumps lo-
cated behind front lower panel of the appliance).
At the bottle end of the PVC chemical hoses, slide the rigid plastic tube over each hose then push
the brass bottle weight onto the end of each hose, now place the hose , tube and bottle weight
into the correct chemical bottle.
Ensure the correct chemical tubes now go to the corresponding chemical bottles.
WARNING
: Only rinse aids and detergents developed for commercial glass and dishwashers are
to be used, rinse aids must be suitable for water temperatures of 104°f or higher.
4.0 Commissioning
4.0 Commissioning
Internal prime switch located
on the chemical pump
bracket, Classeq recommends
that this is only used by quali-
fied service engineers