background image

3.0     Installation

3.0     Installation

 

 

 
3.1        The site : 

Ensure that there is sufficient space for the installation, servicing and easy access to all main      
breaker switches / valves (i.e. electricity and water). 
 
Ensure that the surface the appliance is going to be installed onto is adequately stable and capable 
of supporting the appliance during normal operation, listed below are the approximate machine 
weights when fully laden during normal operation.  
 
C200G, C300G, C500U and C750U must be installed onto a metal stand in accordance with 

CSA 

168, clause 5.10

 (

C

anadian 

S

tandards 

A

ssociation)

 

 
Once installed ensure that the appliance is stable and secure, with its weight being distributed 
equally and does not tilt more than 3° in any direction. 

 

If the appliance is being installed onto a stand or table, ensure it is capable of withstanding the ‘Fully 
loaded’ weight  for the appliance stated below. 

3.2        Electrical connection : 

All electrical connections MUST be carried out by an authorized technician and in accordance with 
local regulations. 
As a minimum ‘

Classeq

’ recommends that the following standards are maintained : 

 

• 

All appliances must be connected via a circuit breaker or some other protective device, 
for the rating of the device refer to either the rating plate on the appliance or the last 
page of this manual. 

 

• 

Supply breaker switch must have all pole separation of more than 1/8 inch (3mm). 

 

• 

The cabinet of the appliance must be grounded, the connection stud is located at the rear of the 
appliance (a suitable ring terminal shall be required), this is in addition to the main electric ground. 

 

3.2.1     Electrical rating : 

For the electrical rating details, please refer to either the rating plate on the appliance or the last  
page of this manual. 
 
Each appliance is designed to run at either 208v or 240v AC, without any modifications, please note 
that the ratings between the two voltages do change. 
 

3.2.2     Connection : 

The main electrical connection must be made via the field terminal block, which is located : 
 

• 

C200G, C500U, C300G and C750U 

- Under the top panel, front right hand side of the 

appliance. 

 

• 

C850P

 - Behind the front lower panel, located at the bottom of the control panel. 

 
For supply connections, use copper wires suitable for at least 194ºF (90ºc ), of the    following sizes 
 

• 

C200G and C500U 

minimum wire gauge 

 

=  14 AWG  (2.5mm²) minimum gauge 

 

• 

C300G, C750U and C850P 

= 8 AWG  (10mm²) minimum gauge 

Machine sizes 

Weight 

(fully loaded)

 

Weight 

(transport / shipping)

 

C200G  &  C500U 

198 lbs (90 Kgs) 

165 lbs (75 Kgs) 

C300G  &  C750U 

298 lbs (135 Kgs) 

198 lbs (90 Kgs) 

C850P 

386 lbs (175 Kgs) 

287 lbs (130 Kgs) 

Page 2 

Содержание C200G

Страница 1: ...Installation Installation Operators Manual Operators Manual C200G C300G C200G C300G C500U C750U C850P C500U C750U C850P Part number 902 0002 Revision C DISHWASHERS COMMERCIAL 51GA ...

Страница 2: ...counter range of glass and dishwashers Section Title Page s 1 Safety instructions 1 2 The appliance 1 3 Installation 2 4 4 Commissioning 4 5 5 Operation 6 7 6 Cleaning 8 7 Trouble shooting 8 10 LM C200G Wiring diagram C200G C500U 11 LM C750U Wiring diagram C300G C750U 12 LM C850P Wiring diagram C850P 13 ...

Страница 3: ...instructed in section 5 of this manual 1 5 Failure malfunction In the event of a failure malfunction the main electrical and water supplies MUST be turned off at the source and not just at the machine 1 6 Repairs and spare parts The appliance must only be repaired by a Classeq approved technician using genuine Classeq spare parts 2 0 The appliance 2 0 The appliance 2 1 Unpacking Use suitable means...

Страница 4: ...tective device for the rating of the device refer to either the rating plate on the appliance or the last page of this manual Supply breaker switch must have all pole separation of more than 1 8 inch 3mm The cabinet of the appliance must be grounded the connection stud is located at the rear of the appliance a suitable ring terminal shall be required this is in addition to the main electric ground...

Страница 5: ...e with the instructions located near the field terminal block on the appliance Field terminal block Hot 1 Live 1 Hot 2 Live 2 Hot 3 3ph units only Ground Earth 3 3 2 Drainage systems To ensure that the appliance correctly drains ensure the correct configuration is true for the appliance All installations must be with a running P trap to ensure hygiene C200G C300G C500U and C750U Diameter 1 40mm st...

Страница 6: ... lower panel and the other inside the machine Classeq would recommend that the external switch is used for priming the chemical Depress and hold switch To fully prime this will take approx 1 minutes 90 seconds 4 1 Rinse aid detergent Ensure PVC chemical hoses are attached correctly to the individual chemical pumps pumps lo cated behind front lower panel of the appliance At the bottle end of the PV...

Страница 7: ... the timers the timers are located C200G C500U C300G and C750U Under the top panel of the appliance C850P Behind the front lower panel on the control panel Machine sizes Rinse aid Cycle Deter gent Cycle C200G 5 10 C300G 5 10 C500U 5 10 C750U 5 10 C850P 5 10 Pre set values in seconds 4 4 Demonstration Classeq recommends that prior to leaving the site installation the installer demonstrates the foll...

Страница 8: ...ator for mains electricity and water supply C200G C500U C300G C750U 1 Power lamp Red 2 ON OFF Button 3 ON OFF Lamp Yellow 4 Machine Ready lamp Green 5 Wash Button 6 Cycle lamp 7 Selector switch optional on C850P only In addition to these switches there are two further switches on the front of the appliance Rinse Aid Prime button Refer to section 4 1 1 of this manual Continual wash button optional ...

Страница 9: ...progress though the cycle during which time the Cycle lamp will be illuminated At the end of the cycle open the door and remove the basket then reload the machine and repeat as required 5 6 Draining During normal operation your appliance will automatically drain away any excess water Classeq recommends if your appliance is not being used for a prolonged period of time the machine must be completel...

Страница 10: ...ppliance now remove the individual wash and rinse jets from each arm and wash in warm soapy water ensuring all debris are removed then rinse in clean water before reassembling and fitting back into the appliance WARNING Before cleaning the wash chamber ensure all sharp items such as broken glass or other items which could cause injury are removed carefully Now wipe the inside of the wash chamber e...

Страница 11: ... is turned ON at the source Drain appliance fully then try again to fill the machine drain as per instructions 5 6 of this manual 7 2 Appliance fills slowly Check water supply valve is fully open Check water supply pressure should be above 30 lbs per square inch if not ask your dealer to install a booster pump to increase water pressure Check and clean rinse jets located on the wash arms within th...

Страница 12: ...oftener required If connected to a water softener replenish the salt within the softener as per the water softener instructions 7 6 Overfilling Drain appliance fully then try again to fill the machine drain as per instructions 5 6 of this manual Check and clean all filters within the appliance Check that the stand pipe drain is not clogged blocked If the appliance continues to overfill turn off bo...

Страница 13: ...2 6 9 L9 Mc Ready Lamp 22 A2 A1 B1 15 18 16 ES 07 T5 RA timer 80 01 55 A2 A1 B1 15 18 16 ES 07 T6 Soap timer 80 01 55 Dishwash select 7 12 1 4 SRS2 Wash trip 76 7 12 12 1 IS1 Inlet sol val 67 Rinse Aid Soap L N L N 8LPP4DS P5 Chemical Pump Assy 61 60 E PE 7 12 4 65 Sw5 R Aid Prime 1213C BLACK 110 L N DP2 P2 Drain Pump DPS25 091 66 7 12 102 C1 W P Capacitor 68 DS400 05 11 C2 R P Capacitor 1274WC344...

Страница 14: ... Rinse Pump UP60 159 63 DS400 05 11 C2 R P Capacitor 1274WC34400 68 7 14 10 1 Sw17 Door Sw 19 11 12 A1 A2 14 31 32 34 21 22 24 CT5 R element Cont 45 11 12 A1 A2 14 31 32 34 21 22 24 CONT 30 CT10 W Element Cont 46 11 12 A1 A2 14 31 32 34 21 22 24 CONT 30 CT15 Cycle Latch 49 7 12 6 8 L6 Supply lamp 20 7 12 6 9 L9 Mc Ready Lamp 22 11 12 14 APS6 Rinse APS Single Oval 18 7 12 1 4 SRS2 Wash trip 76 7 12...

Страница 15: ... timer 80 01 55 Dishwash select L N HY306 E1 Wash Element 80 7 12 1 4 SRS2 Wash op trip 76 7 12 12 1 IS1 Inlet sol val 67 Rinse Aid Soap L N L N 8LPP4DS P5 Chem Pump Assy 61 60 E PE 7 12 4 65 Sw5 R Aid Prime 1213C BLACK 110 L N DP2 P2 Drain Pump DPS25 091 66 7 12 102 C1 W P Capacitor 68 C LC N E DS500 05 10 P6 Rinse Pump UP60 159 63 DS400 05 11 C2 R P Capacitor 1274WC34400 68 7 12 1 4 SRS13 RE op ...

Страница 16: ...Classeq Inc 1006 Corporate Lane Export PA15632 Tel 724 733 2391 Fax 724 733 2491 Notes ...

Отзывы: