10.7 Frequency
Range
Accuracy
Maximum
Resolution
Overload
protection
Input Amplitude
10 Hz
– 10 MHz
±(0.1 % + 4)
0.01 Hz
1000 V DC
/ 750 V AC
200 mV ≤ a ≤
30 V RMS
When measuring on line frequency or duty cycle under AC Voltage and Current
measurement mode, the input amplitude and frequency response must satisfy
the following requirement:
Input amplitude ≥ range x 30 %
Frequency response ≤ 1 kHz
10.8 Diode Test
Resolution
Remarks
Overload protection
0.001 V
Open circuit voltage around 2.8 V
1000 V DC / 750 V AC
10.9 Continuity Test
Resolution
Overload protection
0.1 Ω
1000 V DC / 750 V AC