ELECTRICAL CONNECTIONS

This product is provided with a 13 amp, 230 volt (50Hz), BS 1363 plug, for connection
to a standard, domestic electrical supply. Should the plug need changing at any
time, ensure that a plug of identical specification is used.

WARNING!

This appliance is of Double Insulation construction

No earth conductor is provided. The two wires in the mains lead should be wired
up in accordance with the following colour code:

Blue

Neutral

Brown

Live

Connect the BROWN coloured cord to the plug terminal marked a letter “L”
Connect the BLUE coloured cord to the plug terminal marked a letter “N”

If this appliance is fitted with a plug which is moulded on to the electric cable (i.e.
non-rewireable) please note:

1.

The plug must be thrown away if it is cut from the electric cable. There is a
danger of electric shock if it is subsequently inserted into a socket outlet.

2.

Never use the plug without the fuse cover fitted.

3.

Should you wish to replace a detachable fuse carrier, ensure that the correct
replacement is used (as indicated by marking or colour code).

4.

Replacement fuse covers can be obtained from your local dealer or most
electrical stockists.

Fuse Rating

The fuse in the plug must be replaced with one of the same rating (

13 amps

) and

this replacement must be approved to BS1362.

If in doubt, consult a qualified electrician. Do not attempt any electrical repairs yourself.

Cable Extension

Do not use an extension longer than 10 metres and one where the conductors, are
less than 1.5mm

2

.

If used outdoors, ensure the extension cable is designed for outdoor use.

6

24. NEVER use a cutting-off wheel for side grinding.

25. ALWAYS ensure the work is properly secured or supported.

26. Do not allow flying sparks to fall on sensitive areas. Be aware of fire risks.

27. When not in use always store in a dry clean environment and out of reach of

children.

Additionally, ALWAYS keep these instructions in a safe place for future reference.

Содержание CON115

Страница 1: ...OPERATING MAINTENANCE INSTRUCTIONS 4 115mm ANGLE GRINDER Model No CON115 4 115mm ANGLE GRINDER GC0911 ...

Страница 2: ...22mm Sound Power Level 103dBLWA Sound Pressure Level 89 9dBLWA Vibration Level 2 7m s2 Weight Net 2 7kg Part No 6470140 Please note that the details and specifications contained herein are correct at the time of going to print However CLARKE International reserve the right to change specifications at any time without prior notice ...

Страница 3: ...returned to their place of purchase no product can be returned to us without prior permission This guarantee does not effect your statutory rights CONTENTS Specifications 2 Safety Precautions 3 Additional Precautions for Angle Grinders 5 Electrical Connections 6 Features 7 Assembly 7 Operation 8 Maintenance 8 Troubleshootiing 9 Spare Parts Service Contacts 9 Spare Parts 10 Declaration of Conformit...

Страница 4: ...NDED ACCESSORIES The use of improper accessories could be hazardous 11 NEVER LEAVE THE TOOL RUNNING UNATTENDED Turn power OFF Do not leave the tool until it comes to a complete stop 12 AVOID DANGEROUS ENVIRONMENT Don t use power tools in damp or wet locations or expose them to rain Keep your work area well illuminated DO NOT USE in an explosive atmosphere near paint flammable liquids etc 13 KEEP C...

Страница 5: ...ed of at least 11 000RPM 13 Check the disc carefully for cracks or damage before operation Replace cracked or damaged wheels discs immediately 14 Take care not to damage the spindle or wheel flanges as damage to these parts could result in wheel disc breakage 15 ALWAYS hold the tool firmly in BOTH hands 16 Before using the tool on an actual workpiece allow it to run briefly checking for vibration ...

Страница 6: ...utlet 2 Never use the plug without the fuse cover fitted 3 Should you wish to replace a detachable fuse carrier ensure that the correct replacement is used as indicated by marking or colour code 4 Replacement fuse covers can be obtained from your local dealer or most electrical stockists Fuse Rating The fuse in the plug must be replaced with one of the same rating 13 amps and this replacement must...

Страница 7: ... 4 Tighten the flange using the tool provided locking the spindle by pressing the Spindle Lock button andtaking care to ensure the wheel is still sitting snugly centred over the flange bosses Care should be taken also NOT to overtighten the outer flange 1 ON OFF Switch A TheON OFFswitch A isprovidedwithasafety lock button B The lock button B must be held in before the trigger can be squeezed in to...

Страница 8: ...witch A in Fig 1 is provided with a safety lock button B to prevent accidental starting To operate fully depress the trigger switch and depressing the safety lock button B To stop release the lock button and the trigger switch The grinder will slow down and stop MAINTENANCE IMPORTANT Before carrying out any maintenance tasks ALWAYS disconnect the tool from the mains electrical supply Before Each U...

Страница 9: ...onsult your Clarke dealer Sparking Motor gets hot 1 Work load too heavy 1 Reduce force applied to tool 2 Low supply voltage 2 Ensure supply voltage is correct If extension cable is used ensure it is of the correct value and is fully unreeled Excessive vibration 1 Wheel not mounted 1 Check and rectify correctly 2 Bearings worn 2 Consult your Clarke dealer PARTS SERVICE TEL 020 8988 7400 PARTS SERVI...

Страница 10: ...1506 7 Guard Securing Screw HTCON11507 8 Guard Locking Screw HTCON11508 Flange Release Tool HTCON11509 The following Grinding Wheels Cutting Discs are available from your Clarke dealer 1 Metal Grinding DPC 115mm x 6mm thickness Part No 6470705 2 Metal Cutting DPC 115mm x 3mm thickness Part No 6470775 3 Masonry Cutting DPC 115mm x 3mm thickness Part No 6470735 PARTS DIAGRAM ...