15
WARNING! THIS APPLIANCE MUST BE EARTHED.
a. Arc/TIG 85 & 110
Plug the power cable directly to 230 volt (50Hz), 13amp domestic electrical supply
We strongly recommend that this be done via a Residual Current Device (RCD).
ELECTRICAL CONNECTIONS
Fuse Rating
The fuse in the plug must be replaced with one of the same rating (
13 amps
) and
this replacement must be ASTA approved to BS1362.
b. Arc/TIG 155
Connect the mains lead, through a suitably fused isolator switch, to a 230 Volt
(50Hz) electrical supply, with a fuse rating in accordance with the specifications
shown on page 21.
A standard 13 Amp plug MUST NOT be used with these welders.
c. BOTH MODELS
IMPORTANT: The wires in the mains lead are coloured in accordance with the
following code:
Green & Yellow .......... Earth
Blue .......... Neutral
Brown .......... Live
As the colours of the flexible cord of this appliance may not correspond with the
coloured markings identifying terminals in your plug, proceed as follows:
•
Connect GREEN & YELLOW cord to plug terminal marked with a letter “E” or
Earth symbol “ ”, or coloured GREEN or GREEN & YELLOW.
•
Connect BROWN cord to plug terminal marked letter “L” or coloured RED.
•
Connect BLUE cord to plug terminal marked letter “N” or coloured BLACK.
Extension Cable
If an extension cable is fitted, ensure the minimum cross section of the conductor
is 1.5mm
2
for up to 15 metres in length, and 2.5mm
2
for up to 25 metres.