21
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
TROUBLESHOOTING
STORAGE
If the tool is to be stored or is idle for longer than 24 hours, run a few drops of
air-line oil into the air inlet and depress the trigger in order to lubricate the
internal parts.
When not in use, the tool should be disconnected from the air supply and
stored in a dry place out of the reach of children. Avoid storing in a damp
environment.
Avoid storing air tools where the temperature is below 0
o
C.
SYMPTOM
PROBLEM
SOLUTION
Tool runs at normal
speed but slows down
under any load.
1. Excessive pressure on
tool.
2. Motor parts worn.
3. Worn or sticking
mechanism due to
lack of lubricant.
1. Reduce the force
applied to the tool.
2. Return to CLARKE dealer
for repair.
3. Drip air tool lubricating
oil into air inlet. Allow oil
to soak moving parts
before using.
Tool runs slowly. Air flows
weakly from exhaust.
1. Motor parts jammed
with gum/dirt.
2. Regulator in closed
position.
3. General airflow
blocked by dirt.
1. Examine inlet air filter for
cleanliness.
2. Adjust regulator to open
position.
3. Operate tool in short
bursts.
Tool will not run. Air flows
freely from exhaust.
1. Motor vanes stuck
due to buildup of
foreign material.
1. Disconnect air supply
and rotate tool assembly
manually.
2. Try operating tool in
short bursts.
3. Tap motor housing gently
with a rubber mallet.
4. Drip a few drops of air
tool lubricating oil into air
inlet to soak moving
parts.
Tool will not shut off.
1. O-rings damaged or
ill-fitting in seat.
1. Return to CLARKE dealer
for repair.