![CKD Rapiflow FSM2 Series Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/ckd/rapiflow-fsm2-series/rapiflow-fsm2-series_instruction-manual_2611675006.webp)
[SM-385853-A]
−
5
−
●
Although the mounting is "unrestricted in vertical/horizontal
direction", the flow rate may vary depending on difference in the
mounting orientations or piping conditions.
About Mounting
●
The display integrated type's flow rate meter uses a liquid crystal
display, which may be difficult to read depending on the angle.
●
Do not install the product in a manner that the bodies contact each
other. The evolution of heat from each other could cause the
generation body's temperature rise and enhance the change in
characteristics or the deterioration of the resin materials. When using
the products in a row, set intervals of distance of 10 mm and over.
●
This product can be installed in any direction; top, bottom, left, or
right.
Note of Integrated needle valve type
●
This valve cannot be used as a stop valve that has no leakage. Slight
leakage is allowed in product specifications.
●
The flow path in the needle valve is not completely free of dust
generation. A final clean filter should be used in circuits where dust
generation could be a problem.
●
Do not turn the dial forcibly when fully closing or opening it (0.05 N m
or less). Do not use the lock nut to adjust the needle. Otherwise this
could cause needle galling or damage.
●
The set flow rate may vary if turning the dial of the needle valve
forcibly when fully closing. Take care not to turn the dial forcibly when
setting a very small flow rate.
●
When you install the panel, please install this product after piping
etc.
●
Check that lock nuts are not loose. Actuator speed cannot be
controlled if the lock nut is loose.
●
A stopper mechanism is provided, but damage could result if
the needle is turned too far.
Bracket (separate sales)
Model no. : FSM2-LB1
Port size: Push-in joint 4
、
6
、
8
、
10
Rc1/8
、
Rc1/4
、
M5
Bracket (separate sales)
Model no. : FSM2-LB2
Port size: Rc1/2
!
CAUTION:
Vertical mount
(with bottom thread)
Horizontal mount
(with through hole)
Bracket mount (with bracket)
Installed screw
Installed screw
Installed screw
Installed screw
Installed screw
!
CAUTION:
Discontinue
Содержание Rapiflow FSM2 Series
Страница 49: ...48 PRODUCTS SM 385853 A FSM2 N P A15 Flow range 501 102 2 M3 depth5 Discontinue...
Страница 52: ...51 PRODUCTS SM 385853 A FSM2 A A15 Flow range 501 102 2 M3 depth5 Discontinue...
Страница 55: ...54 PRODUCTS SM 385853 A FSM2 A H08 H10 S08 B Flow range 500 101 201 FSM2 A A15 B Flow range 501 102 Discontinue...