[SM-385853-A]
−
12
−
INSTALLATION
1
1.
INSTALLATION
1.1
Piping
<
Caution
>
Arrange piping so that the flow direction agrees with the direction of the arrow indicated on the
sensor body.
Flash the pipe to remove foreign substances and swarf, etc., in inside of pipe before piping.
When piping a sensor, do not apply excessive screw-in and load torques to the port.
When piping, apply a spanner on the metal section not to apply forces onto the resin section.
[Reference value]
Set
screw
Tightening torque
N
・
m
M5
1.0 to 1.5
Rc1/8
3 to 5
Rc1/4
6 to 8
Rc1/2
16 to 18
When piping, care must be taken that sealing tape and adhesive must not enter into the inside.
If a push-in joint is used, the tube must be inserted certainly. Pulls the tube to check that the tube
not be come out
Flow direction
Flow direction
Discontinue